Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

481

matching recommendations
Reset
SIC 26 Paper And Allied Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AM0196 # 01 Y:1994 01 1994 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $33,400 $0 Implemented
AM0196 # 02 Y:1994 02 1994 USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS $14,100 $19,783 Implemented
AM0196 # 03 Y:1994 03 1994 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $22,270 $51,520 Not Implemented
AM0196 # 04 Y:1994 04 1994 INSULATE BARE EQUIPMENT $7,280 $500 Not Implemented
AM0196 # 05 Y:1994 05 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $382 $349 Implemented
AM0197 # 01 Y:1994 01 1994 INCREASE AMOUNT OF CONDENSATE RETURNED $18,256 $3,400 Not Implemented
AM0197 # 02 Y:1994 02 1994 REPAIR AND ELIMINATE STEAM LEAKS $4,825 $1,400 Implemented
AM0197 # 03 Y:1994 03 1994 INSULATE BARE EQUIPMENT $3,602 $425 Not Implemented
AM0197 # 04 Y:1994 04 1994 INSTALL / REPAIR INSULATION ON STEAM LINES $1,491 $460 Implemented
AM0197 # 05 Y:1994 05 1994 USE SYNTHETIC LUBRICANT $1,090 $0 Not Implemented
AM0197 # 06 Y:1994 06 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $473 $919 Not Implemented
AM0197 # 07 Y:1994 07 1994 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $220 $0 Implemented
AM0187 # 01 Y:1993 01 1993 TURN OFF EQUIPMENT WHEN NOT IN USE $16,530 $465 Not Implemented
AM0187 # 02 Y:1993 02 1993 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $6,720 $0 Implemented
AM0187 # 03 Y:1993 03 1993 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $3,800 $370 Implemented
AM0187 # 04 Y:1993 04 1993 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $2,150 $1,000 Implemented
AM0187 # 05 Y:1993 05 1993 MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT $2,130 $0 Not Implemented
AM0187 # 06 Y:1993 06 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,740 $1,882 Not Implemented
AM0187 # 07 Y:1993 07 1993 USE SYNTHETIC LUBRICANT $190 $0 Implemented
AM0180 # 01 Y:1993 01 1993 OPERATE DISTILLATION COLUMNS EFFICIENTLY $3,360 $13,900 Not Implemented
AM0180 # 02 Y:1993 02 1993 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $2,570 $1,515 Not Implemented
AM0180 # 03 Y:1993 03 1993 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $1,650 $0 Not Implemented
AM0180 # 04 Y:1993 04 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $755 $400 Implemented
AM0180 # 05 Y:1993 05 1993 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $640 $1,115 Implemented
AM0165 # 01 Y:1992 01 1992 USE DRYING OVEN (BATCH TYPE) ON ALTERNATE DAYS OR OTHER OPTIMUM SCHEDULE TO RUN EQUIPMENT WITH FULL LOADS $23,570 $1,350 Implemented