Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
7,948
matching recommendationsSIC | 26 | Paper And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OD0037 # 03 Y:1995 | 03 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $612 | $748 | Implemented |
OD0037 # 04 Y:1995 | 04 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $720 | $1,035 | Not Implemented |
OD0037 # 05 Y:1995 | 05 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,883 | $480 | Implemented |
OD0037 # 06 Y:1995 | 06 | 1995 | INSTALL OCCUPANCY SENSORS | $545 | $433 | Not Implemented |
OD0037 # 07 Y:1995 | 07 | 1995 | TURN OFF EQUIPMENT WHEN NOT IN USE | $477 | $0 | Implemented |
OD0037 # 08 Y:1995 | 08 | 1995 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $994 | $0 | Not Implemented |
OD0037 # 09 Y:1995 | 09 | 1995 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,437 | $910 | Implemented |
UD0463 # 01 Y:1995 | 01 | 1995 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $493 | $0 | Not Implemented |
UD0463 # 02 Y:1995 | 02 | 1995 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $4,512 | $12,000 | Not Implemented |
UD0463 # 03 Y:1995 | 03 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,335 | $16,387 | Not Implemented |
WV0068 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,697 | $662 | Implemented |
WV0068 # 02 Y:1995 | 02 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,299 | $5,490 | Implemented |
WV0068 # 03 Y:1995 | 03 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,044 | $1,240 | Implemented |
WV0068 # 04 Y:1995 | 04 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $271 | $295 | Implemented |
WV0068 # 05 Y:1995 | 05 | 1995 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $733 | $15 | Not Implemented |
WV0068 # 06 Y:1995 | 06 | 1995 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $773 | $2,700 | Not Implemented |
WV0068 # 07 Y:1995 | 07 | 1995 | INSTALL / REPAIR INSULATION ON STEAM LINES | $791 | $1,071 | Implemented |
WV0068 # 08 Y:1995 | 08 | 1995 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $8,325 | $3,300 | Implemented |
WV0068 # 09 Y:1995 | 09 | 1995 | USE EVAPORATION TO CONCENTRATE MATERIAL | $11,456 | $5,400 | Not Implemented |
KG0028 # 01 Y:1995 | 01 | 1995 | INSTALL TIMERS AND/OR THERMOSTATS | $2,738 | $1,050 | Implemented |
KG0028 # 02 Y:1995 | 02 | 1995 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,629 | $0 | Not Implemented |
KG0028 # 03 Y:1995 | 03 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,216 | $1,102 | Not Implemented |
KG0028 # 04 Y:1995 | 04 | 1995 | USE HIGHEST TEMPERATURE FOR CHILLING OR COLD STORAGE | $1,953 | $0 | Not Implemented |
KG0028 # 05 Y:1995 | 05 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,100 | $3,090 | Implemented |
OK0469 # 01 Y:1995 | 01 | 1995 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $9,273 | $20,856 | Implemented |