Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

105

matching recommendations
Reset
SIC 26 Paper And Allied Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0513 # 08 Y:1997 08 1997 RECYCLE WHITE WATER $729,526 $4,000,000 Not Implemented
OK0513 # 09 Y:1997 09 1997 $46,860 $72,000 Implemented
OK0469 # 01 Y:1995 01 1995 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $9,273 $20,856 Implemented
OK0469 # 02 Y:1995 02 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,961 $18,975 Not Implemented
OK0469 # 03 Y:1995 03 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $642 $1,638 Not Implemented
OK0469 # 04 Y:1995 04 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $305 $356 Implemented
OK0469 # 05 Y:1995 05 1995 INSTALL OCCUPANCY SENSORS $218 $520 Implemented
OK0469 # 06 Y:1995 06 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $172 $102 Implemented
OK0447 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,233 $8,800 Implemented
OK0447 # 02 Y:1994 02 1994 INSULATE BARE EQUIPMENT $505 $526 Implemented
OK0447 # 03 Y:1994 03 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,645 $0 Not Implemented
OK0447 # 04 Y:1994 04 1994 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $9,581 $2,618 Not Implemented
OK0447 # 05 Y:1994 05 1994 RECOVER WASTE HEAT FROM EQUIPMENT $1,652 $832 Implemented
OK0447 # 06 Y:1994 06 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $815 $2,199 Implemented
OK0447 # 07 Y:1994 07 1994 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $43,497 $198,000 Not Implemented
OK0287 # 01 Y:1989 01 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $490 $456 Not Implemented
OK0287 # 02 Y:1989 02 1989 INSULATE BARE EQUIPMENT $492 $308 Not Implemented
OK0287 # 03 Y:1989 03 1989 IMPROVE LUBRICATION PRACTICES $438 $5,122 Implemented
OK0287 # 04 Y:1989 04 1989 INSULATE BARE EQUIPMENT $480 $245 Not Implemented
OK0287 # 05 Y:1989 05 1989 INSTALL TIMERS AND/OR THERMOSTATS $389 $980 Implemented
OK0287 # 06 Y:1989 06 1989 USE RADIANT HEATER FOR SPOT HEATING $2,087 $12,000 Implemented
OK0197 # 01 Y:1986 01 1986 MINIMIZE BOILER BLOWDOWN WITH BETTER FEEDWATER TREATMENT $2,964 $3,200 Implemented
OK0197 # 02 Y:1986 02 1986 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $369 $360 Not Implemented
OK0197 # 03 Y:1986 03 1986 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,954 $1,500 Not Implemented
OK0197 # 04 Y:1986 04 1986 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $547 $80 Implemented