Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
219
matching recommendationsSIC | 26 | Paper And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OD0174 # 04 Y:2000 | 04 | 2000 | METER WASTE WATER | $4,925 | $2,156 | Not Implemented |
OD0174 # 03 Y:2000 | 03 | 2000 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,307 | $2,000 | Not Implemented |
OD0174 # 02 Y:2000 | 02 | 2000 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $864 | $1,000 | Not Implemented |
OD0174 # 01 Y:2000 | 01 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,705 | $2,700 | Not Implemented |
CO0477 # 07 Y:2000 | 07 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20 | $0 | Not Implemented |
CO0477 # 05 Y:2000 | 05 | 2000 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $450 | $1,060 | Not Implemented |
CO0477 # 06 Y:2000 | 06 | 2000 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $220 | $150 | Not Implemented |
CO0477 # 04 Y:2000 | 04 | 2000 | USE OPTIMUM TEMPERATURE | $1,050 | $200 | Not Implemented |
CO0477 # 03 Y:2000 | 03 | 2000 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $1,410 | $970 | Not Implemented |
CO0477 # 02 Y:2000 | 02 | 2000 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $1,530 | $2,000 | Not Implemented |
CO0477 # 01 Y:2000 | 01 | 2000 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $5,760 | $15,500 | Not Implemented |
AR0196 # 05 Y:2000 | 05 | 2000 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE HANDLING COSTS | $46,800 | $4,050 | Not Implemented |
AR0196 # 04 Y:2000 | 04 | 2000 | DEVELOP STANDARD OPERATING PROCEDURES | $3,510 | $0 | Not Implemented |
AR0196 # 03 Y:2000 | 03 | 2000 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $197 | $0 | Not Implemented |
AR0196 # 02 Y:2000 | 02 | 2000 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $222 | $527 | Not Implemented |
AR0196 # 01 Y:2000 | 01 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $426 | $60 | Not Implemented |
SD0259 # 05 Y:2000 | 05 | 2000 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $82,000 | $0 | Not Implemented |
SD0259 # 03 Y:2000 | 03 | 2000 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $16,900 | $0 | Not Implemented |
SD0259 # 04 Y:2000 | 04 | 2000 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $24,552 | $14,000 | Not Implemented |
SD0259 # 01 Y:2000 | 01 | 2000 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $20,193 | $26,000 | Not Implemented |
SD0259 # 02 Y:2000 | 02 | 2000 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $4,440 | $40 | Implemented |
SF0202 # 04 Y:2000 | 04 | 2000 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $941 | $5,000 | Not Implemented |
SF0202 # 01 Y:2000 | 01 | 2000 | TURN OFF EQUIPMENT WHEN NOT IN USE | $698 | $0 | Implemented |
SF0202 # 03 Y:2000 | 03 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,800 | $11,610 | Not Implemented |
SF0202 # 02 Y:2000 | 02 | 2000 | INSTALL OCCUPANCY SENSORS | $960 | $600 | Implemented |