Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

17

matching recommendations
Reset
SIC 261 Pulp Mills
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0580 # 06 Y:2019 06 2019 REPAIR OR REPLACE STEAM TRAPS $1,791 $5,731 Implemented
WV0580 # 05 Y:2019 05 2019 INSULATE BARE EQUIPMENT $2,238 $2,550 Implemented
WV0580 # 04 Y:2019 04 2019 RECOVER WASTE HEAT FROM EQUIPMENT $8,437 $15,360 Implemented
WV0580 # 03 Y:2019 03 2019 USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR $52,590 $160,314 Not Implemented
WV0580 # 02 Y:2019 02 2019 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $143,962 $6,000 Implemented
WV0580 # 01 Y:2019 01 2019 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $265,061 $31,000 Not Implemented
WV0365 # 09 Y:2007 09 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,552 $0 Implemented
WV0365 # 11 Y:2007 11 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,863 $2,514 Implemented
WV0365 # 10 Y:2007 10 2007 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,435 $0 Implemented
WV0365 # 01 Y:2007 01 2007 RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER $1,979,852 $607,600 Not Implemented
WV0365 # 08 Y:2007 08 2007 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $6,649 $9,450 Implemented
WV0365 # 07 Y:2007 07 2007 USE STEAM PRESSURE REDUCTION TO GENERATE POWER $9,063 $39,000 Not Implemented
WV0365 # 06 Y:2007 06 2007 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $17,614 $8,565 Implemented
WV0365 # 05 Y:2007 05 2007 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $29,685 $75,450 Implemented
WV0365 # 04 Y:2007 04 2007 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $75,759 $228,975 Implemented
WV0365 # 03 Y:2007 03 2007 DEVELOP A REPAIR/REPLACE POLICY $87,247 $12,756 Not Implemented
WV0365 # 02 Y:2007 02 2007 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $279,065 $31,300 Not Implemented