Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
22
matching recommendationsSIC | 2631 | Paperboard Mills |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0038 # 08 Y:1994 | 08 | 1994 | INSTALL / REPAIR INSULATION ON STEAM LINES | $7,763 | $1,001 | Not Implemented |
WV0038 # 07 Y:1994 | 07 | 1994 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $807 | $0 | Implemented |
WV0038 # 06 Y:1994 | 06 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $962 | $150 | Not Implemented |
WV0038 # 05 Y:1994 | 05 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $7,334 | $0 | Implemented |
WV0038 # 04 Y:1994 | 04 | 1994 | DIRECT WARMEST AIR TO COMBUSTION INTAKE | $81,877 | $4,570 | Not Implemented |
WV0038 # 03 Y:1994 | 03 | 1994 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $32,800 | $5,000 | Not Implemented |
WV0038 # 02 Y:1994 | 02 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,081 | $118,620 | Implemented |
WV0038 # 01 Y:1994 | 01 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,370 | $3,491 | Implemented |
UD0266 # 06 Y:1988 | 06 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,639 | $11,475 | Implemented |
UD0266 # 08 Y:1988 | 08 | 1988 | BURN FOSSIL FUEL TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR AND USE STEAM EXHAUST FOR HEAT | $155,320 | $875,000 | Not Implemented |
UD0266 # 07 Y:1988 | 07 | 1988 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $9,266 | $30,000 | Implemented |
UD0266 # 05 Y:1988 | 05 | 1988 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $23,169 | $20,000 | Implemented |
UD0266 # 04 Y:1988 | 04 | 1988 | REPAIR AND ELIMINATE STEAM LEAKS | $21,603 | $5,000 | Implemented |
UD0266 # 03 Y:1988 | 03 | 1988 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $10,213 | $7,000 | Not Implemented |
UD0266 # 02 Y:1988 | 02 | 1988 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $462 | $0 | Implemented |
UD0266 # 01 Y:1988 | 01 | 1988 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $7,611 | $600 | Implemented |
UD0135 # 01 Y:1984 | 01 | 1984 | INSTALL / REPAIR INSULATION ON STEAM LINES | $12,421 | $3,300 | Implemented |
UD0135 # 06 Y:1984 | 06 | 1984 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $37,591 | $0 | Not Implemented |
UD0135 # 05 Y:1984 | 05 | 1984 | USE DRYING OVEN (BATCH TYPE) ON ALTERNATE DAYS OR OTHER OPTIMUM SCHEDULE TO RUN EQUIPMENT WITH FULL LOADS | $54,580 | $0 | Implemented |
UD0135 # 04 Y:1984 | 04 | 1984 | INSTALL SET-BACK TIMERS | $4,080 | $770 | Implemented |
UD0135 # 03 Y:1984 | 03 | 1984 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $8,600 | $20,000 | Not Implemented |
UD0135 # 02 Y:1984 | 02 | 1984 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $152,310 | $140,000 | Not Implemented |