Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,551
matching recommendationsSIC | 265 | Paperboard Containers And Boxes |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0144 # 05 Y:1992 | 05 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,338 | $2,560 | Not Implemented |
WI0144 # 06 Y:1992 | 06 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,483 | $0 | Not Implemented |
WI0144 # 07 Y:1992 | 07 | 1992 | INSTALL SET-BACK TIMERS | $2,086 | $400 | Not Implemented |
WI0144 # 08 Y:1992 | 08 | 1992 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,000 | $0 | Not Implemented |
WI0144 # 09 Y:1992 | 09 | 1992 | INSTALL TIMERS AND/OR THERMOSTATS | $957 | $200 | Implemented |
WI0144 # 10 Y:1992 | 10 | 1992 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $423 | $0 | Implemented |
RU0142 # 01 Y:1992 | 01 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,782 | $0 | Not Implemented |
RU0142 # 02 Y:1992 | 02 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,151 | $0 | Not Implemented |
RU0142 # 03 Y:1992 | 03 | 1992 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,812 | $0 | Not Implemented |
RU0142 # 04 Y:1992 | 04 | 1992 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,143 | $0 | Not Implemented |
RU0142 # 05 Y:1992 | 05 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $222 | $0 | Implemented |
RU0139 # 01 Y:1992 | 01 | 1992 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $10,985 | $201 | Implemented |
RU0139 # 02 Y:1992 | 02 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,401 | $68 | Implemented |
RU0139 # 03 Y:1992 | 03 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,050 | $2,523 | Implemented |
RU0139 # 04 Y:1992 | 04 | 1992 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $10,165 | $2,500 | Implemented |
RU0139 # 05 Y:1992 | 05 | 1992 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $921 | $500 | Implemented |
RU0139 # 06 Y:1992 | 06 | 1992 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $14,070 | $0 | Implemented |
TN0462 # 01 Y:1992 | 01 | 1992 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $12,369 | $9,880 | Not Implemented |
TN0462 # 02 Y:1992 | 02 | 1992 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,871 | $5,400 | Not Implemented |
TN0462 # 03 Y:1992 | 03 | 1992 | KEEP LAMPS AND REFLECTORS CLEAN | $5,076 | $5,335 | Not Implemented |
TN0462 # 04 Y:1992 | 04 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,393 | $400 | Not Implemented |
TN0462 # 05 Y:1992 | 05 | 1992 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $422 | $660 | Not Implemented |
TN0462 # 06 Y:1992 | 06 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,504 | $390 | Not Implemented |
TN0462 # 07 Y:1992 | 07 | 1992 | INSTALL SET-BACK TIMERS | $271 | $0 | Not Implemented |
TN0462 # 08 Y:1992 | 08 | 1992 | IMPROVE LUBRICATION PRACTICES | $116 | $0 | Not Implemented |