Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,551
matching recommendationsSIC | 265 | Paperboard Containers And Boxes |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0321 # 01 Y:1990 | 01 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $14,217 | $37,000 | Implemented |
UD0321 # 02 Y:1990 | 02 | 1990 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,310 | $7,500 | Implemented |
UD0321 # 03 Y:1990 | 03 | 1990 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,760 | $1,100 | Implemented |
UD0321 # 04 Y:1990 | 04 | 1990 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $10,068 | $14,000 | Not Implemented |
WI0086 # 01 Y:1990 | 01 | 1990 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $39,882 | $0 | Not Implemented |
WI0086 # 02 Y:1990 | 02 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,034 | $2,719 | Not Implemented |
WI0086 # 03 Y:1990 | 03 | 1990 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,311 | $0 | Not Implemented |
WI0086 # 04 Y:1990 | 04 | 1990 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,293 | $7,000 | Not Implemented |
WI0086 # 05 Y:1990 | 05 | 1990 | INSTALL STORM WINDOWS AND DOORS | $1,028 | $2,448 | Not Implemented |
WI0086 # 06 Y:1990 | 06 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $799 | $250 | Not Implemented |
WI0086 # 07 Y:1990 | 07 | 1990 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $679 | $500 | Not Implemented |
WI0086 # 08 Y:1990 | 08 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $508 | $2,000 | Not Implemented |
TN0395 # 01 Y:1990 | 01 | 1990 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $5,279 | $0 | Not Implemented |
TN0395 # 02 Y:1990 | 02 | 1990 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $1,544 | $3,195 | Implemented |
TN0395 # 03 Y:1990 | 03 | 1990 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $3,308 | $300 | Not Implemented |
TN0395 # 04 Y:1990 | 04 | 1990 | KEEP LAMPS AND REFLECTORS CLEAN | $2,426 | $5,083 | Not Implemented |
TN0395 # 05 Y:1990 | 05 | 1990 | INSTALL SET-BACK TIMERS | $1,470 | $0 | Implemented |
TN0395 # 06 Y:1990 | 06 | 1990 | CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN | $1,403 | $245 | Implemented |
TN0395 # 07 Y:1990 | 07 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $568 | $660 | Not Implemented |
TN0395 # 08 Y:1990 | 08 | 1990 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $368 | $0 | Not Implemented |
TN0395 # 09 Y:1990 | 09 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $418 | $195 | Implemented |
TN0395 # 10 Y:1990 | 10 | 1990 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $15,293 | $31,800 | Not Implemented |
WI0072 # 01 Y:1989 | 01 | 1989 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,236 | $0 | Implemented |
WI0072 # 02 Y:1989 | 02 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $564 | $3,238 | Not Implemented |
WI0072 # 03 Y:1989 | 03 | 1989 | IMPROVE LUBRICATION PRACTICES | $1,866 | $0 | Implemented |