IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,551

matching recommendations
Reset
SIC 265 Paperboard Containers And Boxes
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0138 # 11 Y:1984 11 1984 INSTALL TIMERS AND/OR THERMOSTATS $661 $0 Implemented
KU0138 # 12 Y:1984 12 1984 ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE $884 $120 Implemented
KU0138 # 13 Y:1984 13 1984 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $112 $0 Not Implemented
UD0130 # 01 Y:1984 01 1984 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $47,885 $110,000 Not Implemented
UD0130 # 02 Y:1984 02 1984 REDUCE GLAZED AREAS IN BUILDINGS $7,927 $5,145 Not Implemented
UD0130 # 03 Y:1984 03 1984 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $466 $578 Not Implemented
UD0130 # 04 Y:1984 04 1984 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $26,850 $30,000 Not Implemented
OK0138 # 01 Y:1984 01 1984 INSTALL TIMERS AND/OR THERMOSTATS $9,036 $600 Implemented
OK0138 # 02 Y:1984 02 1984 OPTIMIZE PLANT POWER FACTOR $569 $550 Not Implemented
OK0138 # 03 Y:1984 03 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $916 $1,209 Implemented
OK0130 # 01 Y:1984 01 1984 INSTALL TIMERS AND/OR THERMOSTATS $1,811 $640 Implemented
OK0130 # 02 Y:1984 02 1984 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $3,941 $5,508 Implemented
OK0130 # 03 Y:1984 03 1984 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,191 $180 Implemented
OK0130 # 04 Y:1984 04 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $262 $1,000 Implemented
OK0123 # 01 Y:1984 01 1984 INCREASE AMOUNT OF CONDENSATE RETURNED $1,080 $1,600 Not Implemented
OK0123 # 02 Y:1984 02 1984 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $2,438 $300 Implemented
OK0123 # 03 Y:1984 03 1984 INSTALL TIMERS AND/OR THERMOSTATS $596 $0 Implemented
OK0123 # 04 Y:1984 04 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $233 $231 Implemented
OK0123 # 05 Y:1984 05 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,651 $9,570 Not Implemented
OK0123 # 06 Y:1984 06 1984 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $727 $0 Not Implemented
TN0186 # 01 Y:1983 01 1983 OPTIMIZE PLANT POWER FACTOR $1,180 $27,000 Not Implemented
TN0186 # 02 Y:1983 02 1983 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,100 $800 Not Implemented
TN0196 # 01 Y:1983 01 1983 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $1,218 $150 Not Implemented
TN0196 # 02 Y:1983 02 1983 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE $47 $0 Not Implemented
UD0097 # 01 Y:1983 01 1983 INSTALL STORM WINDOWS AND DOORS $6,434 $6,887 Not Implemented