Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,551
matching recommendationsSIC | 265 | Paperboard Containers And Boxes |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0138 # 11 Y:1984 | 11 | 1984 | INSTALL TIMERS AND/OR THERMOSTATS | $661 | $0 | Implemented |
KU0138 # 12 Y:1984 | 12 | 1984 | ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE | $884 | $120 | Implemented |
KU0138 # 13 Y:1984 | 13 | 1984 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $112 | $0 | Not Implemented |
UD0130 # 01 Y:1984 | 01 | 1984 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $47,885 | $110,000 | Not Implemented |
UD0130 # 02 Y:1984 | 02 | 1984 | REDUCE GLAZED AREAS IN BUILDINGS | $7,927 | $5,145 | Not Implemented |
UD0130 # 03 Y:1984 | 03 | 1984 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $466 | $578 | Not Implemented |
UD0130 # 04 Y:1984 | 04 | 1984 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $26,850 | $30,000 | Not Implemented |
OK0138 # 01 Y:1984 | 01 | 1984 | INSTALL TIMERS AND/OR THERMOSTATS | $9,036 | $600 | Implemented |
OK0138 # 02 Y:1984 | 02 | 1984 | OPTIMIZE PLANT POWER FACTOR | $569 | $550 | Not Implemented |
OK0138 # 03 Y:1984 | 03 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $916 | $1,209 | Implemented |
OK0130 # 01 Y:1984 | 01 | 1984 | INSTALL TIMERS AND/OR THERMOSTATS | $1,811 | $640 | Implemented |
OK0130 # 02 Y:1984 | 02 | 1984 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $3,941 | $5,508 | Implemented |
OK0130 # 03 Y:1984 | 03 | 1984 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,191 | $180 | Implemented |
OK0130 # 04 Y:1984 | 04 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $262 | $1,000 | Implemented |
OK0123 # 01 Y:1984 | 01 | 1984 | INCREASE AMOUNT OF CONDENSATE RETURNED | $1,080 | $1,600 | Not Implemented |
OK0123 # 02 Y:1984 | 02 | 1984 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,438 | $300 | Implemented |
OK0123 # 03 Y:1984 | 03 | 1984 | INSTALL TIMERS AND/OR THERMOSTATS | $596 | $0 | Implemented |
OK0123 # 04 Y:1984 | 04 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $233 | $231 | Implemented |
OK0123 # 05 Y:1984 | 05 | 1984 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,651 | $9,570 | Not Implemented |
OK0123 # 06 Y:1984 | 06 | 1984 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $727 | $0 | Not Implemented |
TN0186 # 01 Y:1983 | 01 | 1983 | OPTIMIZE PLANT POWER FACTOR | $1,180 | $27,000 | Not Implemented |
TN0186 # 02 Y:1983 | 02 | 1983 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,100 | $800 | Not Implemented |
TN0196 # 01 Y:1983 | 01 | 1983 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,218 | $150 | Not Implemented |
TN0196 # 02 Y:1983 | 02 | 1983 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $47 | $0 | Not Implemented |
UD0097 # 01 Y:1983 | 01 | 1983 | INSTALL STORM WINDOWS AND DOORS | $6,434 | $6,887 | Not Implemented |