IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

192

matching recommendations
Reset
SIC 265 Paperboard Containers And Boxes
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0271 # 02 Y:1989 02 1989 USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE $5,826 $297 Implemented
KU0271 # 03 Y:1989 03 1989 KEEP BOILER TUBES CLEAN $5,300 $1,500 Implemented
KU0271 # 04 Y:1989 04 1989 INSULATE BARE EQUIPMENT $3,940 $900 Not Implemented
KU0271 # 05 Y:1989 05 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,327 $6,000 Not Implemented
KU0271 # 06 Y:1989 06 1989 USE RADIANT HEATER FOR SPOT HEATING $3,371 $6,000 Not Implemented
KU0271 # 07 Y:1989 07 1989 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,406 $100 Implemented
KU0271 # 08 Y:1989 08 1989 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,370 $7,134 Implemented
KU0271 # 09 Y:1989 09 1989 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,445 $1,500 Implemented
KU0271 # 10 Y:1989 10 1989 TREAT AND REUSE RINSE WATERS $1,110 $1,500 Not Implemented
KU0234 # 01 Y:1987 01 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,784 $3,862 Implemented
KU0234 # 02 Y:1987 02 1987 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $4,993 $8,000 Not Implemented
KU0234 # 03 Y:1987 03 1987 RECOVER WASTE HEAT FROM EQUIPMENT $5,345 $4,000 Implemented
KU0234 # 04 Y:1987 04 1987 INSTALL TURBULATORS $4,336 $6,311 Not Implemented
KU0234 # 05 Y:1987 05 1987 IMPROVE LUBRICATION PRACTICES $4,229 $0 Not Implemented
KU0234 # 06 Y:1987 06 1987 INSULATE BARE EQUIPMENT $3,013 $5,000 Implemented
KU0234 # 07 Y:1987 07 1987 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,044 $0 Implemented
KU0234 # 08 Y:1987 08 1987 REPAIR AND ELIMINATE STEAM LEAKS $1,504 $140 Implemented
KU0234 # 09 Y:1987 09 1987 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,385 $0 Implemented
KU0234 # 10 Y:1987 10 1987 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $544 $400 Implemented
KU0234 # 11 Y:1987 11 1987 TURN OFF EQUIPMENT WHEN NOT IN USE $370 $0 Implemented
KU0224 # 01 Y:1987 01 1987 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $5,708 $10,000 Not Implemented
KU0224 # 02 Y:1987 02 1987 INSULATE BARE EQUIPMENT $62 $1,000 Implemented
KU0224 # 03 Y:1987 03 1987 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $204 $10 Implemented
KU0226 # 01 Y:1987 01 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,452 $2,376 Not Implemented
KU0226 # 02 Y:1987 02 1987 INSULATE BARE EQUIPMENT $5,171 $1,302 Implemented