Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
55
matching recommendationsSIC | 2653 | Corrugated And Solid Fiber Boxes |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
NC0067 # 06 Y:1995 | 06 | 1995 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,162 | $0 | Not Implemented |
NC0067 # 10 Y:1995 | 10 | 1995 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $200 | $100 | Implemented |
NC0067 # 09 Y:1995 | 09 | 1995 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,713 | $600 | Implemented |
NC0067 # 07 Y:1995 | 07 | 1995 | REDUCE VENTILATION AIR | $21,249 | $25,000 | Not Implemented |
NC0067 # 05 Y:1995 | 05 | 1995 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $9,392 | $45,000 | Implemented |
NC0067 # 04 Y:1995 | 04 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $618 | $680 | Not Implemented |
NC0067 # 03 Y:1995 | 03 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,692 | $919 | Implemented |
NC0067 # 02 Y:1995 | 02 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,315 | $1,122 | Implemented |
NC0067 # 01 Y:1995 | 01 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,790 | $360 | Implemented |
NC0067 # 08 Y:1995 | 08 | 1995 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $9,347 | $34,448 | Not Implemented |
NC0036 # 01 Y:1994 | 01 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,746 | $690 | Implemented |
NC0036 # 02 Y:1994 | 02 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,746 | $500 | Implemented |
NC0036 # 03 Y:1994 | 03 | 1994 | USE POWER DURING OFF-PEAK PERIODS | $6,360 | $2,040 | Not Implemented |
NC0036 # 04 Y:1994 | 04 | 1994 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $12,033 | $24,000 | Not Implemented |
NC0036 # 05 Y:1994 | 05 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,337 | $12,750 | Implemented |
NC0024 # 08 Y:1994 | 08 | 1994 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $15,127 | $25,000 | Not Implemented |
NC0024 # 07 Y:1994 | 07 | 1994 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,700 | $0 | Not Implemented |
NC0024 # 06 Y:1994 | 06 | 1994 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,360 | $4,000 | Not Implemented |
NC0024 # 05 Y:1994 | 05 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $7,875 | $16,390 | Not Implemented |
NC0024 # 04 Y:1994 | 04 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $8,771 | $10,880 | Implemented |
NC0024 # 03 Y:1994 | 03 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,562 | $360 | Implemented |
NC0024 # 02 Y:1994 | 02 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,577 | $2,946 | Implemented |
NC0024 # 01 Y:1994 | 01 | 1994 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $12,358 | $1,420 | Not Implemented |
NC0015 # 06 Y:1993 | 06 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,316 | $330 | Implemented |
NC0015 # 05 Y:1993 | 05 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $2,985 | $600 | Not Implemented |