Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

2,519

matching recommendations
Reset
SIC 2653 Corrugated And Solid Fiber Boxes
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WM0125 # 11 Y:2018 11 2018 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $71 $0 Not Implemented
WM0125 # 10 Y:2018 10 2018 INSTALL OCCUPANCY SENSORS $86 $136 Not Implemented
WM0125 # 09 Y:2018 09 2018 INSTALL OCCUPANCY SENSORS $200 $855 Not Implemented
WM0125 # 08 Y:2018 08 2018 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $284 $360 Not Implemented
WM0125 # 07 Y:2018 07 2018 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $293 $0 Implemented
WM0125 # 06 Y:2018 06 2018 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $791 $1,806 Not Implemented
WM0125 # 05 Y:2018 05 2018 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,042 $1,525 Not Implemented
WM0125 # 04 Y:2018 04 2018 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $5,087 $2,215 Implemented
WM0125 # 03 Y:2018 03 2018 USE SYNTHETIC LUBRICANT $11,015 $21,250 Not Implemented
WM0125 # 02 Y:2018 02 2018 USE SOLAR HEAT TO MAKE ELECTRICTY $17,677 $48,514 Not Implemented
WM0125 # 01 Y:2018 01 2018 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $20,273 $13,601 Not Implemented
NL0011 # 01 Y:2017 01 2017 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $6,874 $0 Not Implemented
NL0011 # 02 Y:2017 02 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,747 $20,139 Implemented
NL0011 # 04 Y:2017 04 2017 ELIMINATE PRACTICE OF MIXING WASTE STREAMS $982 $0 Implemented
NL0011 # 03 Y:2017 03 2017 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,135 $1,571 Not Implemented
AM0720 # 09 Y:2016 09 2016 INSTALL OCCUPANCY SENSORS $970 $280 Not Implemented
AM0720 # 08 Y:2016 08 2016 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $760 $250 Not Implemented
AM0720 # 07 Y:2016 07 2016 USE SYNTHETIC LUBRICANT $5,856 $0 Not Implemented
AM0720 # 06 Y:2016 06 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,600 $5,030 Implemented
AM0720 # 05 Y:2016 05 2016 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $10,389 $0 Not Implemented
AM0720 # 04 Y:2016 04 2016 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $10,240 $0 Implemented
AM0720 # 03 Y:2016 03 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $11,170 $800 Implemented
AM0720 # 02 Y:2016 02 2016 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $10,440 $2,000 Implemented
AM0720 # 01 Y:2016 01 2016 CHECK FOR ACCURACY OF UTILITY / POWER METERS $189,624 $0 Implemented
NC0581 # 08 Y:2016 08 2016 DEVELOP A REPAIR/REPLACE POLICY $2,508 $5,865 Not Implemented