Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

111

matching recommendations
Reset
SIC 2653 Corrugated And Solid Fiber Boxes
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0093 # 04 Y:1987 04 1987 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $1,279 $2,690 Implemented
CO0093 # 05 Y:1987 05 1987 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $109 $70 Implemented
CO0093 # 06 Y:1987 06 1987 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $6,787 $300 Implemented
CO0093 # 07 Y:1987 07 1987 DIRECT WARMEST AIR TO COMBUSTION INTAKE $1,065 $400 Implemented
CO0093 # 08 Y:1987 08 1987 REPAIR AND ELIMINATE STEAM LEAKS $2,521 $300 Implemented
CO0093 # 09 Y:1987 09 1987 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,732 $150 Implemented
CO0093 # 10 Y:1987 10 1987 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $609 $180 Implemented
CO0093 # 11 Y:1987 11 1987 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $374 $1,167 Implemented
CO0093 # 12 Y:1987 12 1987 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $14,707 $1,100 Not Implemented
CO0093 # 13 Y:1987 13 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,292 $409 Implemented
CO0062 # 01 Y:1986 01 1986 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,721 $40 Implemented
CO0062 # 02 Y:1986 02 1986 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $10,638 $9,200 Implemented
CO0062 # 03 Y:1986 03 1986 USE RADIANT HEATER FOR SPOT HEATING $7,549 $15,000 Not Implemented
CO0062 # 04 Y:1986 04 1986 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,765 $3,300 Not Implemented
CO0062 # 05 Y:1986 05 1986 IMPROVE LUBRICATION PRACTICES $3,995 $0 Implemented
CO0062 # 06 Y:1986 06 1986 REPAIR AND ELIMINATE STEAM LEAKS $3,931 $200 Implemented
CO0062 # 07 Y:1986 07 1986 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $1,953 $2,824 Not Implemented
CO0062 # 08 Y:1986 08 1986 INSTALL TURBULATORS $947 $750 Not Implemented
CO0062 # 09 Y:1986 09 1986 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $934 $200 Implemented
CO0062 # 10 Y:1986 10 1986 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $491 $300 Implemented
CO0062 # 11 Y:1986 11 1986 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $584 $20 Not Implemented
CO0062 # 12 Y:1986 12 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,862 $627 Implemented
CO0080 # 01 Y:1986 01 1986 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $11,565 $500 Implemented
CO0080 # 02 Y:1986 02 1986 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $10,145 $300 Implemented
CO0080 # 03 Y:1986 03 1986 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $7,035 $5,500 Not Implemented