Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
123
matching recommendationsSIC | 2656 | Sanitary Food Containers |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0248 # 11 Y:2000 | 11 | 2000 | INSTALL SYSTEM TO COLLECT SCRAP | $13,426 | $11,836 | Implemented |
UF0226 # 01 Y:1999 | 01 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,552 | $0 | Not Implemented |
UF0226 # 02 Y:1999 | 02 | 1999 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,196 | $0 | Not Implemented |
UF0226 # 03 Y:1999 | 03 | 1999 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $10,378 | $50 | Not Implemented |
UF0226 # 04 Y:1999 | 04 | 1999 | INSTALL OCCUPANCY SENSORS | $1,110 | $955 | Not Implemented |
UF0226 # 05 Y:1999 | 05 | 1999 | INITIATE A TOTAL QUALITY MANAGEMENT PROGRAM | $78,207 | $22,390 | Not Implemented |
UF0226 # 06 Y:1999 | 06 | 1999 | USE WASTE HEAT WITH A CLOSED-CYCLE GAS TURBINE-GENERATOR SET TO COGENERATE ELECTRICITY AND HEAT | $200,838 | $1,090,000 | Not Implemented |
UF0226 # 07 Y:1999 | 07 | 1999 | PAY BILLS ON TIME TO AVOID LATE FEES | $1,863 | $0 | Not Implemented |
WI0267 # 01 Y:1996 | 01 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $27,762 | $8,906 | n/a |
WI0267 # 02 Y:1996 | 02 | 1996 | USE SYNTHETIC LUBRICANT | $16,841 | $0 | n/a |
WI0267 # 03 Y:1996 | 03 | 1996 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $14,729 | $45,000 | n/a |
WI0267 # 04 Y:1996 | 04 | 1996 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $13,635 | $39,000 | n/a |
WI0267 # 05 Y:1996 | 05 | 1996 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $9,054 | $16,740 | n/a |
WI0267 # 06 Y:1996 | 06 | 1996 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $6,670 | $0 | n/a |
WI0267 # 07 Y:1996 | 07 | 1996 | SCHEDULE ROUTINE MAINTENANCE DURING NON-OPERATING PERIODS | $4,867 | $0 | n/a |
WI0267 # 08 Y:1996 | 08 | 1996 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $3,040 | $0 | n/a |
WI0267 # 09 Y:1996 | 09 | 1996 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $2,236 | $5,000 | n/a |
SD0080 # 01 Y:1994 | 01 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $33,824 | $60,230 | Implemented |
SD0080 # 02 Y:1994 | 02 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $11,011 | $9,431 | Implemented |
SD0080 # 03 Y:1994 | 03 | 1994 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $2,204 | $300 | Implemented |
SD0080 # 04 Y:1994 | 04 | 1994 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $21,874 | $1,500 | Not Implemented |
SD0080 # 05 Y:1994 | 05 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,021 | $220 | Implemented |
SD0080 # 06 Y:1994 | 06 | 1994 | REPAIR AND ELIMINATE STEAM LEAKS | $8,391 | $300 | Implemented |
SD0080 # 07 Y:1994 | 07 | 1994 | REPAIR OR REPLACE STEAM TRAPS | $90,394 | $5,000 | Implemented |
SD0080 # 08 Y:1994 | 08 | 1994 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $4,743 | $10,500 | Not Implemented |