Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,112

matching recommendations
Reset
SIC 267 Misc. Converted Paper Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0215 # 06 Y:1991 06 1991 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $346 $193 Implemented
MA0215 # 07 Y:1991 07 1991 USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM $28,458 $24,853 Implemented
CO0200 # 01 Y:1990 01 1990 INSTALL TIMERS AND/OR THERMOSTATS $4,200 $2,250 Not Implemented
CO0200 # 02 Y:1990 02 1990 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $420 $280 Implemented
CO0200 # 03 Y:1990 03 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,570 $320 Not Implemented
CO0200 # 04 Y:1990 04 1990 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $1,500 $250 Implemented
CO0200 # 05 Y:1990 05 1990 RECOVER WASTE HEAT FROM EQUIPMENT $950 $2,000 Not Implemented
CO0200 # 06 Y:1990 06 1990 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $580 $990 Not Implemented
CO0200 # 07 Y:1990 07 1990 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $540 $1,800 Not Implemented
CO0200 # 08 Y:1990 08 1990 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $500 $700 Not Implemented
RU0095 # 01 Y:1990 01 1990 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,594 $2,500 Implemented
RU0095 # 02 Y:1990 02 1990 INSTALL / REPAIR INSULATION ON STEAM LINES $2,404 $72 Not Implemented
RU0095 # 03 Y:1990 03 1990 REPAIR AND ELIMINATE STEAM LEAKS $4,881 $0 Implemented
RU0095 # 04 Y:1990 04 1990 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $4,156 $375 Not Implemented
RU0095 # 05 Y:1990 05 1990 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $454 $269 Not Implemented
RU0095 # 06 Y:1990 06 1990 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,859 $0 Not Implemented
RU0095 # 07 Y:1990 07 1990 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $865 $584 Not Implemented
RU0095 # 08 Y:1990 08 1990 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $3,140 $4,878 Implemented
OR0079 # 01 Y:1990 01 1990 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $5,596 $312 Not Implemented
OR0079 # 02 Y:1990 02 1990 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $148 $50 Implemented
OR0079 # 03 Y:1990 03 1990 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,902 $1,000 Implemented
OR0079 # 04 Y:1990 04 1990 OPTIMIZE PLANT POWER FACTOR $473 $1,200 Not Implemented
OR0079 # 05 Y:1990 05 1990 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $7,374 $31,672 Not Implemented
KU0302 # 01 Y:1990 01 1990 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $980 $0 Implemented
KU0302 # 02 Y:1990 02 1990 SHUT OFF PILOTS IN STANDBY EQUIPMENT $254 $0 Implemented