Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
129
matching recommendationsSIC | 267 | Misc. Converted Paper Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MA0502 # 06 Y:2001 | 06 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,771 | $3,000 | Not Implemented |
MA0493 # 01 Y:2001 | 01 | 2001 | ADOPT IN-HOUSE MATERIAL GENERATION | $48,702 | $180,000 | Not Implemented |
MA0493 # 02 Y:2001 | 02 | 2001 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,846 | $0 | Implemented |
MA0493 # 03 Y:2001 | 03 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,613 | $150 | Implemented |
MA0493 # 04 Y:2001 | 04 | 2001 | OPTIMIZE PLANT POWER FACTOR | $2,165 | $3,750 | Not Implemented |
MA0493 # 05 Y:2001 | 05 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $516 | $1,000 | Implemented |
MA0493 # 06 Y:2001 | 06 | 2001 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $161 | $100 | Implemented |
MA0493 # 07 Y:2001 | 07 | 2001 | PAY BILLS ON TIME TO AVOID LATE FEES | $350 | $0 | Implemented |
MA0464 # 01 Y:2000 | 01 | 2000 | REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE | $15,077 | $36,000 | Not Implemented |
MA0464 # 02 Y:2000 | 02 | 2000 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $193 | $0 | Implemented |
MA0464 # 03 Y:2000 | 03 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $145 | $440 | Implemented |
MA0461 # 01 Y:2000 | 01 | 2000 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $15,869 | $768 | Implemented |
MA0461 # 02 Y:2000 | 02 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $6,834 | $18,630 | Implemented |
MA0461 # 03 Y:2000 | 03 | 2000 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $4,117 | $128,000 | Not Implemented |
MA0461 # 04 Y:2000 | 04 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,838 | $30,000 | Implemented |
MA0461 # 05 Y:2000 | 05 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,501 | $1,630 | Implemented |
MA0461 # 06 Y:2000 | 06 | 2000 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,272 | $0 | Implemented |
MA0461 # 07 Y:2000 | 07 | 2000 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $848 | $0 | Implemented |
MA0396 # 01 Y:1997 | 01 | 1997 | USE MAGNETIC TECHNOLOGY TO TREAT WATER | $7,580 | $9,347 | Not Implemented |
MA0396 # 02 Y:1997 | 02 | 1997 | INSTALL SMALLER BOILER (INCREASE HIGH FIRE DUTY CYCLE) | $5,492 | $11,700 | Implemented |
MA0396 # 03 Y:1997 | 03 | 1997 | USE COOLING TOWER WATER INSTEAD OF REFRIGERATION | $4,207 | $14,329 | Not Implemented |
MA0396 # 04 Y:1997 | 04 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,606 | $75 | Implemented |
MA0396 # 05 Y:1997 | 05 | 1997 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,409 | $60 | Implemented |
MA0396 # 06 Y:1997 | 06 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $819 | $102 | Not Implemented |
MA0396 # 07 Y:1997 | 07 | 1997 | TURN OFF EQUIPMENT WHEN NOT IN USE | $182 | $132 | Not Implemented |