Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

3,112

matching recommendations
Reset
SIC 267 Misc. Converted Paper Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
HO0094 # 07 Y:1994 07 1994 INSTALL OCCUPANCY SENSORS $441 $400 Implemented
HO0094 # 08 Y:1994 08 1994 USE DRYING OVEN (BATCH TYPE) ON ALTERNATE DAYS OR OTHER OPTIMUM SCHEDULE TO RUN EQUIPMENT WITH FULL LOADS $812 $500 Not Implemented
MO0134 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,184 $4,474 Implemented
MO0134 # 02 Y:1994 02 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,768 $1,168 Implemented
MO0134 # 03 Y:1994 03 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $5,895 $5,382 Implemented
MO0134 # 04 Y:1994 04 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $694 $90 Implemented
MO0134 # 05 Y:1994 05 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,574 $4,266 Not Implemented
MO0134 # 06 Y:1994 06 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $237 $350 Not Implemented
CO0319 # 01 Y:1994 01 1994 RECYCLE WASTE INK AND CLEANUP SOLVENT $11,210 $6,150 Not Implemented
CO0319 # 02 Y:1994 02 1994 DISTILL CONTAMINATED SOLVENTS FOR REUSE $6,370 $7,200 Not Implemented
CO0319 # 03 Y:1994 03 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,310 $5,820 Not Implemented
CO0319 # 04 Y:1994 04 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,730 $460 Not Implemented
CO0319 # 05 Y:1994 05 1994 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $4,320 $6,800 Not Implemented
CO0319 # 06 Y:1994 06 1994 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,000 $460 Not Implemented
CO0319 # 07 Y:1994 07 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,000 $840 Not Implemented
CO0319 # 08 Y:1994 08 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,100 $210 Not Implemented
NV0010 # 01 Y:1994 01 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,502 $482 Implemented
NV0010 # 02 Y:1994 02 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,150 $1,950 Implemented
NV0010 # 03 Y:1994 03 1994 ADJUST BURNERS FOR EFFICIENT OPERATION $4,473 $400 Implemented
NV0010 # 04 Y:1994 04 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $521 $120 Implemented
NV0010 # 05 Y:1994 05 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $136 $200 Implemented
NV0010 # 06 Y:1994 06 1994 UTILIZE A LESS EXPENSIVE COOLING METHOD $1,179 $700 Not Implemented
NV0010 # 07 Y:1994 07 1994 INSULATE BARE EQUIPMENT $181 $138 Implemented
BD0013 # 01 Y:1994 01 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,745 $2,250 Not Implemented
BD0013 # 02 Y:1994 02 1994 RECOVER WASTE HEAT FROM EQUIPMENT $7,926 $100 Not Implemented