Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

611

matching recommendations
Reset
SIC 2671 Paper Coated & Laminated, Packaging
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0585 # 01 Y:1999 01 1999 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $2,155 $2,668 n/a
OK0585 # 02 Y:1999 02 1999 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $-1,464 $4,300 n/a
OK0585 # 03 Y:1999 03 1999 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,788 $0 n/a
OK0585 # 04 Y:1999 04 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,121 $1,162 n/a
OK0585 # 05 Y:1999 05 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $179 $360 n/a
OK0585 # 06 Y:1999 06 1999 INSTALL SET-BACK TIMERS $507 $260 n/a
OK0585 # 07 Y:1999 07 1999 $45,623 $17,000 n/a
OK0585 # 08 Y:1999 08 1999 $147,498 $25,000 n/a
OK0585 # 09 Y:1999 09 1999 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $1,045 $0 n/a
NV0133 # 01 Y:1999 01 1999 REPLACE BOILER $20,745 $14,694 Implemented
NV0133 # 02 Y:1999 02 1999 OPTIMIZE PLANT POWER FACTOR $3,872 $5,370 Not Implemented
NV0133 # 03 Y:1999 03 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $38,194 $38,194 Not Implemented
NV0133 # 04 Y:1999 04 1999 USE RADIANT HEATER FOR SPOT HEATING $6,458 $7,275 Not Implemented
NV0133 # 05 Y:1999 05 1999 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $4,917 $9,200 Not Implemented
NV0133 # 06 Y:1999 06 1999 PAY UTILITY BILLS ON TIME $1,013 $0 Implemented
UF0199 # 01 Y:1998 01 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,796 $7,894 Implemented
UF0199 # 02 Y:1998 02 1998 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,859 $1,286 Not Implemented
UF0199 # 03 Y:1998 03 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,359 $882 Implemented
UF0199 # 04 Y:1998 04 1998 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,910 $1,350 Implemented
UF0199 # 05 Y:1998 05 1998 REPLACE CLOTH RAGS WITH PAPER TOWELS $5,530 $0 Not Implemented
UF0199 # 06 Y:1998 06 1998 USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES $42,668 $0 Not Implemented
UF0199 # 07 Y:1998 07 1998 APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES $11,602 $750 Implemented
UF0199 # 08 Y:1998 08 1998 $12,500 $6,000 Not Implemented
IA0176 # 01 Y:1997 01 1997 REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT $45,488 $20,000 Implemented
IA0176 # 02 Y:1997 02 1997 CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS $30,900 $30,400 Implemented