Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
28
matching recommendationsSIC | 2672 | Paper Coated And Laminated, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
RU0075 # 07 Y:1989 | 07 | 1989 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $4,528 | $6,660 | Not Implemented |
RU0075 # 06 Y:1989 | 06 | 1989 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,572 | $3,800 | Not Implemented |
RU0075 # 05 Y:1989 | 05 | 1989 | INSTALL SET-BACK TIMERS | $1,089 | $80 | Not Implemented |
RU0075 # 04 Y:1989 | 04 | 1989 | INSULATE BARE EQUIPMENT | $2,338 | $218 | Not Implemented |
RU0075 # 03 Y:1989 | 03 | 1989 | IMPROVE LUBRICATION PRACTICES | $780 | $800 | Not Implemented |
RU0075 # 02 Y:1989 | 02 | 1989 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,281 | $0 | Implemented |
RU0075 # 01 Y:1989 | 01 | 1989 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,443 | $650 | Not Implemented |
MA0165 # 04 Y:1989 | 04 | 1989 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $24,781 | $22,722 | Not Implemented |
MA0165 # 03 Y:1989 | 03 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,081 | $500 | Not Implemented |
MA0165 # 01 Y:1989 | 01 | 1989 | INSTALL SET-BACK TIMERS | $502 | $157 | Not Implemented |
MA0165 # 02 Y:1989 | 02 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $1,015 | $840 | Implemented |
CO0152 # 02 Y:1989 | 02 | 1989 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $4,885 | $15,000 | Implemented |
CO0152 # 10 Y:1989 | 10 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,765 | $414 | Implemented |
CO0152 # 09 Y:1989 | 09 | 1989 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $26,900 | $250 | Implemented |
CO0152 # 08 Y:1989 | 08 | 1989 | INSTALL SET-BACK TIMERS | $244 | $400 | Implemented |
CO0152 # 07 Y:1989 | 07 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $1,300 | $5,000 | Implemented |
CO0152 # 06 Y:1989 | 06 | 1989 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,680 | $3,900 | Implemented |
CO0152 # 05 Y:1989 | 05 | 1989 | INSULATE BARE EQUIPMENT | $306 | $500 | Not Implemented |
CO0152 # 04 Y:1989 | 04 | 1989 | INSTALL / REPAIR INSULATION ON STEAM LINES | $610 | $5,000 | Implemented |
CO0152 # 03 Y:1989 | 03 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,650 | $2,560 | Implemented |
CO0152 # 01 Y:1989 | 01 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,440 | $0 | Implemented |
RU0052 # 01 Y:1989 | 01 | 1989 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $19,516 | $2,000 | Implemented |
RU0052 # 02 Y:1989 | 02 | 1989 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $7,753 | $0 | Not Implemented |
RU0052 # 04 Y:1989 | 04 | 1989 | REPLACE FOSSIL FUEL EQUIPMENT WITH ELECTRICAL EQUIPMENT | $3,292 | $6,000 | Implemented |
RU0052 # 05 Y:1989 | 05 | 1989 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $3,251 | $4,500 | Not Implemented |