Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
15
matching recommendationsSIC | 2674 | Bags: Uncoated Paper & Multiwall |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0277 # 01 Y:2001 | 01 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,104 | $0 | Implemented |
UF0277 # 02 Y:2001 | 02 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,130 | $0 | Implemented |
UF0277 # 03 Y:2001 | 03 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,261 | $0 | Not Implemented |
UF0277 # 04 Y:2001 | 04 | 2001 | INSTALL SKYLIGHTS | $20,383 | $0 | Not Implemented |
UF0277 # 05 Y:2001 | 05 | 2001 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $2,497 | $0 | Not Implemented |
UF0277 # 06 Y:2001 | 06 | 2001 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $15,737 | $0 | Not Implemented |
UF0277 # 07 Y:2001 | 07 | 2001 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $14,700 | $0 | Not Implemented |
UF0277 # 08 Y:2001 | 08 | 2001 | DEVELOP A REPAIR/REPLACE POLICY | $8,088 | $0 | Implemented |
UF0277 # 09 Y:2001 | 09 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,962 | $0 | Not Implemented |
UF0277 # 10 Y:2001 | 10 | 2001 | INSTALL OCCUPANCY SENSORS | $1,315 | $0 | Not Implemented |
UF0277 # 11 Y:2001 | 11 | 2001 | REPAIR OR REPLACE STEAM TRAPS | $2,712 | $0 | Implemented |
UF0277 # 12 Y:2001 | 12 | 2001 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $9,600 | $0 | Not Implemented |
UF0277 # 13 Y:2001 | 13 | 2001 | INSTALL DIRECT ACTING UNITS IN PLACE OF COMPRESSED AIR PRESSURE SYSTEM IN SAFETY SYSTEM | $7,281 | $0 | Implemented |
UF0277 # 14 Y:2001 | 14 | 2001 | INSTALL AUTOMATIC PACKING EQUIPMENT | $7,280 | $0 | Not Implemented |
UF0277 # 15 Y:2001 | 15 | 2001 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $540,000 | $0 | Not Implemented |