Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
166
matching recommendationsSIC | 2676 | Sanitary Paper Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0231 # 09 Y:2012 | 09 | 2012 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,123 | $1,160 | Implemented |
MI0231 # 08 Y:2012 | 08 | 2012 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $3,835 | $4,691 | Not Implemented |
MI0231 # 07 Y:2012 | 07 | 2012 | OPTIMIZE PLANT POWER FACTOR | $4,040 | $4,550 | Not Implemented |
MI0231 # 06 Y:2012 | 06 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,414 | $80 | Implemented |
MI0231 # 05 Y:2012 | 05 | 2012 | INSTALL OCCUPANCY SENSORS | $6,801 | $800 | Implemented |
MI0231 # 04 Y:2012 | 04 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,235 | $2,050 | Not Implemented |
MI0231 # 03 Y:2012 | 03 | 2012 | PAY BILLS ON TIME TO AVOID LATE FEES | $13,801 | $480 | Implemented |
MI0231 # 02 Y:2012 | 02 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $18,144 | $1,660 | Implemented |
MI0231 # 01 Y:2012 | 01 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $30,009 | $1,800 | Implemented |
MI0231 # 11 Y:2012 | 11 | 2012 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $1,120 | $1,498 | Not Implemented |
DL0070 # 06 Y:2011 | 06 | 2011 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $104,177 | $157,000 | Implemented |
DL0070 # 09 Y:2011 | 09 | 2011 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $4,701 | $10,500 | Not Implemented |
DL0070 # 10 Y:2011 | 10 | 2011 | USE SOLAR HEAT TO MAKE ELECTRICTY | $33,730 | $1,035,000 | Not Implemented |
DL0070 # 08 Y:2011 | 08 | 2011 | MODERATE COOLING TOWER OUTLET TEMPERATURE | $21,528 | $52,000 | Implemented |
DL0070 # 07 Y:2011 | 07 | 2011 | USE STEAM SPARGING OR INJECTIONS IN PLACE OF INDIRECT HEATING | $4,600 | $10,000 | Not Implemented |
DL0070 # 05 Y:2011 | 05 | 2011 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,782 | $1,800 | Not Implemented |
DL0070 # 04 Y:2011 | 04 | 2011 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $14,330 | $500 | Implemented |
DL0070 # 03 Y:2011 | 03 | 2011 | REDUCE VENTILATION AIR | $2,160 | $45 | Not Implemented |
DL0070 # 02 Y:2011 | 02 | 2011 | REDUCE VENTILATION AIR | $12,200 | $200 | Implemented |
DL0070 # 01 Y:2011 | 01 | 2011 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $136,635 | $120,000 | Implemented |
UU0069 # 04 Y:2004 | 04 | 2004 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $91,960 | $12,500 | Not Implemented |
UU0069 # 01 Y:2004 | 01 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,879 | $11,735 | Implemented |
UU0069 # 02 Y:2004 | 02 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,497 | $268 | Implemented |
UU0069 # 03 Y:2004 | 03 | 2004 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $16,545 | $2,000 | Implemented |
UU0069 # 05 Y:2004 | 05 | 2004 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $34,560 | $0 | Implemented |