Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

166

matching recommendations
Reset
SIC 2676 Sanitary Paper Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MI0231 # 09 Y:2012 09 2012 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,123 $1,160 Implemented
MI0231 # 08 Y:2012 08 2012 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $3,835 $4,691 Not Implemented
MI0231 # 07 Y:2012 07 2012 OPTIMIZE PLANT POWER FACTOR $4,040 $4,550 Not Implemented
MI0231 # 06 Y:2012 06 2012 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $6,414 $80 Implemented
MI0231 # 05 Y:2012 05 2012 INSTALL OCCUPANCY SENSORS $6,801 $800 Implemented
MI0231 # 04 Y:2012 04 2012 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,235 $2,050 Not Implemented
MI0231 # 03 Y:2012 03 2012 PAY BILLS ON TIME TO AVOID LATE FEES $13,801 $480 Implemented
MI0231 # 02 Y:2012 02 2012 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $18,144 $1,660 Implemented
MI0231 # 01 Y:2012 01 2012 TURN OFF EQUIPMENT WHEN NOT IN USE $30,009 $1,800 Implemented
MI0231 # 11 Y:2012 11 2012 UTILIZE A LESS EXPENSIVE COOLING METHOD $1,120 $1,498 Not Implemented
DL0070 # 06 Y:2011 06 2011 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $104,177 $157,000 Implemented
DL0070 # 09 Y:2011 09 2011 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $4,701 $10,500 Not Implemented
DL0070 # 10 Y:2011 10 2011 USE SOLAR HEAT TO MAKE ELECTRICTY $33,730 $1,035,000 Not Implemented
DL0070 # 08 Y:2011 08 2011 MODERATE COOLING TOWER OUTLET TEMPERATURE $21,528 $52,000 Implemented
DL0070 # 07 Y:2011 07 2011 USE STEAM SPARGING OR INJECTIONS IN PLACE OF INDIRECT HEATING $4,600 $10,000 Not Implemented
DL0070 # 05 Y:2011 05 2011 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,782 $1,800 Not Implemented
DL0070 # 04 Y:2011 04 2011 MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION $14,330 $500 Implemented
DL0070 # 03 Y:2011 03 2011 REDUCE VENTILATION AIR $2,160 $45 Not Implemented
DL0070 # 02 Y:2011 02 2011 REDUCE VENTILATION AIR $12,200 $200 Implemented
DL0070 # 01 Y:2011 01 2011 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $136,635 $120,000 Implemented
UU0069 # 04 Y:2004 04 2004 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $91,960 $12,500 Not Implemented
UU0069 # 01 Y:2004 01 2004 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,879 $11,735 Implemented
UU0069 # 02 Y:2004 02 2004 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,497 $268 Implemented
UU0069 # 03 Y:2004 03 2004 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $16,545 $2,000 Implemented
UU0069 # 05 Y:2004 05 2004 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $34,560 $0 Implemented