IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

449

matching recommendations
Reset
SIC 2677 Envelopes
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
HO0150 # 02 Y:1997 02 1997 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $791 $700 Implemented
HO0150 # 03 Y:1997 03 1997 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $413 $310 Implemented
HO0150 # 04 Y:1997 04 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,566 $60 Not Implemented
HO0150 # 05 Y:1997 05 1997 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $9,000 $6,500 Not Implemented
HO0150 # 06 Y:1997 06 1997 REDUCE HEAT GAIN BY WINDOW TINTING $5,161 $7,590 Not Implemented
HO0150 # 07 Y:1997 07 1997 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,238 $20,020 Not Implemented
HO0150 # 08 Y:1997 08 1997 USE RADIANT HEATER FOR SPOT HEATING $956 $3,000 Implemented
HO0150 # 09 Y:1997 09 1997 MINIMIZE WATER USAGE $390 $100 Implemented
AS0179 # 01 Y:1996 01 1996 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $8,521 $21,600 Implemented
AS0179 # 02 Y:1996 02 1996 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $10,187 $7,700 Not Implemented
AS0179 # 03 Y:1996 03 1996 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $8,307 $12,000 Not Implemented
AS0179 # 04 Y:1996 04 1996 INSULATE BARE EQUIPMENT $1,590 $150 Implemented
AS0179 # 05 Y:1996 05 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $25,441 $15,981 Implemented
AS0179 # 06 Y:1996 06 1996 INSTALL OCCUPANCY SENSORS $2,293 $2,325 Implemented
AS0179 # 07 Y:1996 07 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $9,398 $20,641 Implemented
AS0179 # 08 Y:1996 08 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,504 $18,900 Not Implemented
AS0179 # 09 Y:1996 09 1996 MINIMIZE WATER USAGE $1,142 $2,455 Not Implemented
SF0088 # 01 Y:1996 01 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,890 $2,203 Not Implemented
SF0088 # 02 Y:1996 02 1996 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,170 $2,331 Not Implemented
SF0088 # 03 Y:1996 03 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $13,025 $28,020 Not Implemented
SF0088 # 04 Y:1996 04 1996 INSTALL OCCUPANCY SENSORS $426 $1,200 Not Implemented
SF0088 # 05 Y:1996 05 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $856 $1,382 Not Implemented
SF0088 # 06 Y:1996 06 1996 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $3,454 $1,544 Not Implemented
SF0088 # 07 Y:1996 07 1996 OPTIMIZE PLANT POWER FACTOR $1,611 $2,106 Not Implemented
SF0088 # 08 Y:1996 08 1996 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $214 $310 Not Implemented