Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,540
matching recommendationsSIC | 27 | Printing And Publishing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SF0437 # 08 Y:2013 | 08 | 2013 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $15,796 | $43,156 | Implemented |
SF0437 # 09 Y:2013 | 09 | 2013 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,489 | $13,500 | Implemented |
DL0106 # 01 Y:2013 | 01 | 2013 | REDUCE VENTILATION AIR | $50,820 | $2,200 | Implemented |
DL0106 # 02 Y:2013 | 02 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $28,083 | $1,516 | Implemented |
DL0106 # 04 Y:2013 | 04 | 2013 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $102,000 | $2,375,000 | Implemented |
LE0360 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,056 | $8,300 | Implemented |
LE0360 # 06 Y:2013 | 06 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,806 | $3,200 | Implemented |
LE0360 # 08 Y:2013 | 08 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $366 | $80 | Implemented |
LE0360 # 09 Y:2013 | 09 | 2013 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $691 | $700 | Implemented |
LE0360 # 10 Y:2013 | 10 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,342 | $1,000 | Implemented |
WM0024 # 02 Y:2013 | 02 | 2013 | INSTALL OCCUPANCY SENSORS | $950 | $550 | Implemented |
WM0024 # 03 Y:2013 | 03 | 2013 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $6,156 | $0 | Implemented |
WM0024 # 04 Y:2013 | 04 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $287 | $0 | Implemented |
WM0024 # 06 Y:2013 | 06 | 2013 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $827 | $2,009 | Implemented |
WV0467 # 03 Y:2013 | 03 | 2013 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $14,786 | $2,550 | Implemented |
WV0467 # 05 Y:2013 | 05 | 2013 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $9,901 | $1,000 | Implemented |
WV0467 # 06 Y:2013 | 06 | 2013 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $7,844 | $500 | Implemented |
WV0467 # 10 Y:2013 | 10 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,815 | $248 | Implemented |
WV0467 # 11 Y:2013 | 11 | 2013 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,059 | $571 | Implemented |
WV0467 # 12 Y:2013 | 12 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,260 | $45 | Implemented |
UA0097 # 06 Y:2013 | 06 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $6,219 | $2,500 | Implemented |
IP0006 # 01 Y:2012 | 01 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,520 | $0 | Implemented |
IP0006 # 02 Y:2012 | 02 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $980 | $0 | Implemented |
IP0006 # 03 Y:2012 | 03 | 2012 | INSTALL OCCUPANCY SENSORS | $1,771 | $730 | Implemented |
IP0006 # 06 Y:2012 | 06 | 2012 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $18,261 | $92,692 | Implemented |