Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,640
matching recommendationsSIC | 27 | Printing And Publishing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0508 # 01 Y:1996 | 01 | 1996 | INSTALL TIMERS AND/OR THERMOSTATS | $1,243 | $620 | Implemented |
OK0508 # 02 Y:1996 | 02 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $587 | $100 | Implemented |
OK0508 # 03 Y:1996 | 03 | 1996 | INSTALL OCCUPANCY SENSORS | $66 | $945 | Not Implemented |
OK0508 # 04 Y:1996 | 04 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,327 | $8,741 | Implemented |
OK0508 # 05 Y:1996 | 05 | 1996 | INSTALL SPECTRAL REFLECTORS / DELAMP | $359 | $90 | Not Implemented |
OK0508 # 06 Y:1996 | 06 | 1996 | INSTALL SPECTRAL REFLECTORS / DELAMP | $538 | $180 | Not Implemented |
OK0508 # 07 Y:1996 | 07 | 1996 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $600 | $0 | Not Implemented |
UD0503 # 01 Y:1996 | 01 | 1996 | OPTIMIZE PLANT POWER FACTOR | $4,355 | $4,000 | Implemented |
UD0503 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,164 | $12,748 | Not Implemented |
UD0503 # 03 Y:1996 | 03 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $-368 | $10,000 | Implemented |
UD0503 # 04 Y:1996 | 04 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $449 | $500 | Not Implemented |
UD0503 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,143 | $31,020 | Implemented |
UD0503 # 06 Y:1996 | 06 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,120 | $600 | Implemented |
UD0503 # 07 Y:1996 | 07 | 1996 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $5,772 | $500 | Implemented |
UD0503 # 08 Y:1996 | 08 | 1996 | PREVENT EXCESSIVE SOLVENT USAGE (OPERATOR TRAINING) | $28,200 | $0 | Implemented |
MO0186 # 01 Y:1996 | 01 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,830 | $6,997 | Implemented |
MO0186 # 02 Y:1996 | 02 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $11,517 | $20,272 | Implemented |
MO0186 # 03 Y:1996 | 03 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $298 | $0 | Implemented |
MO0186 # 04 Y:1996 | 04 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $7,894 | $0 | Implemented |
MO0186 # 05 Y:1996 | 05 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $17,021 | $27,890 | Implemented |
MO0186 # 06 Y:1996 | 06 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,577 | $90 | Implemented |
MO0186 # 07 Y:1996 | 07 | 1996 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $3,507 | $0 | Not Implemented |
DS0066 # 01 Y:1996 | 01 | 1996 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $21,792 | $21,193 | Implemented |
DS0066 # 02 Y:1996 | 02 | 1996 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $27,874 | $37,150 | Not Implemented |
DS0066 # 03 Y:1996 | 03 | 1996 | PREHEAT BOILER MAKEUP WATER WITH WASTE PROCESS HEAT | $28,580 | $52,000 | Implemented |