Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,640
matching recommendationsSIC | 27 | Printing And Publishing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0115 # 01 Y:1991 | 01 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,348 | $0 | Not Implemented |
AM0115 # 02 Y:1991 | 02 | 1991 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,600 | $7,000 | Not Implemented |
AM0115 # 03 Y:1991 | 03 | 1991 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $2,020 | $3,220 | Not Implemented |
AM0115 # 04 Y:1991 | 04 | 1991 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $923 | $40 | Not Implemented |
AM0115 # 05 Y:1991 | 05 | 1991 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $240 | $0 | Not Implemented |
AM0115 # 06 Y:1991 | 06 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $140 | $213 | Not Implemented |
MA0205 # 01 Y:1991 | 01 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,259 | $13,297 | Implemented |
MA0205 # 02 Y:1991 | 02 | 1991 | INSTALL SET-BACK TIMERS | $2,448 | $161 | Implemented |
MA0205 # 03 Y:1991 | 03 | 1991 | INSTALL TIMERS AND/OR THERMOSTATS | $7,115 | $4,000 | Implemented |
MA0205 # 04 Y:1991 | 04 | 1991 | REPLACE PURCHASED STEAM WITH OTHER ENERGY SOURCE | $15,928 | $0 | Implemented |
MA0205 # 05 Y:1991 | 05 | 1991 | REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY | $614 | $897 | Implemented |
MA0205 # 06 Y:1991 | 06 | 1991 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,637 | $0 | Implemented |
TN0419 # 01 Y:1991 | 01 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $7,626 | $15,520 | Not Implemented |
TN0419 # 02 Y:1991 | 02 | 1991 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,142 | $5,600 | Not Implemented |
TN0419 # 03 Y:1991 | 03 | 1991 | INSTALL / REPAIR INSULATION ON STEAM LINES | $2,007 | $1,042 | Not Implemented |
TN0419 # 04 Y:1991 | 04 | 1991 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,300 | $1,760 | Not Implemented |
TN0419 # 05 Y:1991 | 05 | 1991 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $618 | $0 | Not Implemented |
TN0419 # 06 Y:1991 | 06 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $546 | $517 | Not Implemented |
TN0419 # 07 Y:1991 | 07 | 1991 | INSTALL SET-BACK TIMERS | $417 | $0 | Not Implemented |
TN0419 # 08 Y:1991 | 08 | 1991 | OPTIMIZE PLANT POWER FACTOR | $6,000 | $10,000 | Not Implemented |
RU0106 # 01 Y:1991 | 01 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $798 | $0 | Implemented |
RU0106 # 02 Y:1991 | 02 | 1991 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $648 | $0 | Implemented |
RU0106 # 03 Y:1991 | 03 | 1991 | IMPROVE LUBRICATION PRACTICES | $507 | $800 | Implemented |
RU0106 # 04 Y:1991 | 04 | 1991 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $645 | $500 | Implemented |
RU0106 # 05 Y:1991 | 05 | 1991 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $5,924 | $0 | Implemented |