Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

5,640

matching recommendations
Reset
SIC 27 Printing And Publishing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
LL0336 # 03 Y:2010 03 2010 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $4,848 $1,290 Not Implemented
LL0336 # 04 Y:2010 04 2010 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $3,008 $630 Implemented
LL0336 # 05 Y:2010 05 2010 INSTALL OCCUPANCY SENSORS $1,947 $2,100 Implemented
LL0336 # 06 Y:2010 06 2010 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $1,072 $1,336 Not Implemented
LL0336 # 07 Y:2010 07 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $392 $245 Not Implemented
LL0336 # 08 Y:2010 08 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $370 $127 Not Implemented
LE0305 # 01 Y:2010 01 2010 RECOVER WASTE HEAT FROM EQUIPMENT $81,866 $60,000 Not Implemented
LE0305 # 02 Y:2010 02 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $47,762 $17,000 Not Implemented
LE0305 # 03 Y:2010 03 2010 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $28,242 $1,720 Not Implemented
LE0305 # 04 Y:2010 04 2010 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $27,533 $0 Not Implemented
LE0305 # 05 Y:2010 05 2010 INSTALL TIMERS AND/OR THERMOSTATS $15,838 $250 Not Implemented
LE0305 # 06 Y:2010 06 2010 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $12,566 $35,000 Not Implemented
LE0305 # 07 Y:2010 07 2010 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $11,857 $0 Not Implemented
LE0305 # 08 Y:2010 08 2010 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $8,426 $2,800 Not Implemented
LE0305 # 09 Y:2010 09 2010 INSTALL OCCUPANCY SENSORS $3,000 $900 Not Implemented
UA0056 # 01 Y:2010 01 2010 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $10,865 $38,883 Implemented
UA0056 # 02 Y:2010 02 2010 USE PHOTOCELL CONTROLS $451 $900 Implemented
UA0056 # 03 Y:2010 03 2010 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $2,084 $640 Not Implemented
UA0056 # 04 Y:2010 04 2010 INSTALL TIMERS AND/OR THERMOSTATS $5,615 $2,000 Implemented
UA0056 # 05 Y:2010 05 2010 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $6,045 $240 Implemented
MZ0050 # 01 Y:2010 01 2010 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,053 $1,160 Not Implemented
MZ0050 # 02 Y:2010 02 2010 TURN OFF EQUIPMENT WHEN NOT IN USE $2,616 $0 Implemented
MZ0050 # 03 Y:2010 03 2010 AIR CONDITION ONLY SPACE NECESSARY $24,897 $5,000 Implemented
MZ0050 # 04 Y:2010 04 2010 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $585 $6,000 Implemented
MZ0050 # 05 Y:2010 05 2010 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $916 $1,000 Not Implemented