Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
142
matching recommendationsSIC | 27 | Printing And Publishing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
LE0469 # 02 Y:2019 | 02 | 2019 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $159 | $175 | Not Implemented |
LE0469 # 03 Y:2019 | 03 | 2019 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,321 | $6,000 | Not Implemented |
LE0469 # 05 Y:2019 | 05 | 2019 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,425 | $18,125 | Not Implemented |
LE0469 # 01 Y:2019 | 01 | 2019 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,507 | $1,000 | Not Implemented |
LE0469 # 04 Y:2019 | 04 | 2019 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $18,723 | $23,000 | Not Implemented |
DL0106 # 02 Y:2013 | 02 | 2013 | TURN OFF EQUIPMENT WHEN NOT IN USE | $28,083 | $1,516 | Implemented |
DL0106 # 01 Y:2013 | 01 | 2013 | REDUCE VENTILATION AIR | $50,820 | $2,200 | Implemented |
DL0106 # 05 Y:2013 | 05 | 2013 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $81,500 | $11,200 | Not Implemented |
DL0106 # 04 Y:2013 | 04 | 2013 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $102,000 | $2,375,000 | Implemented |
DL0106 # 03 Y:2013 | 03 | 2013 | INSTALL SPECTRAL REFLECTORS / DELAMP | $58,740 | $5,580 | Not Implemented |
LE0360 # 07 Y:2013 | 07 | 2013 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $2,156 | $5,250 | Not Implemented |
LE0360 # 09 Y:2013 | 09 | 2013 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $691 | $700 | Implemented |
LE0360 # 10 Y:2013 | 10 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,342 | $1,000 | Implemented |
LE0360 # 08 Y:2013 | 08 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $366 | $80 | Implemented |
LE0360 # 05 Y:2013 | 05 | 2013 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,262 | $9,600 | Not Implemented |
LE0360 # 04 Y:2013 | 04 | 2013 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $7,603 | $29,670 | Not Implemented |
LE0360 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,056 | $8,300 | Implemented |
LE0360 # 03 Y:2013 | 03 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,813 | $6,560 | Not Implemented |
LE0360 # 06 Y:2013 | 06 | 2013 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,806 | $3,200 | Implemented |
LE0360 # 02 Y:2013 | 02 | 2013 | INSTALL OCCUPANCY SENSORS | $16,814 | $25,500 | Not Implemented |
LE0223 # 03 Y:2005 | 03 | 2005 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $4,650 | $50 | Implemented |
LE0223 # 02 Y:2005 | 02 | 2005 | REPLACE BOILER | $5,753 | $74,500 | Not Implemented |
LE0223 # 01 Y:2005 | 01 | 2005 | USE SOLAR HEAT TO MAKE ELECTRICTY | $444,462 | $1,100,000 | Not Implemented |
LE0223 # 04 Y:2005 | 04 | 2005 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,831 | $2,500 | Implemented |
LE0223 # 05 Y:2005 | 05 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,281 | $100 | Implemented |