IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,080

matching recommendations
Reset
SIC 2711 Newspapers
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UA0133 # 05 Y:2015 05 2015 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $8,308 $10,240 Implemented
UA0133 # 04 Y:2015 04 2015 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,236 $783 Implemented
UA0133 # 03 Y:2015 03 2015 INSTALL OCCUPANCY SENSORS $3,600 $2,389 Not Implemented
DL0121 # 01 Y:2014 01 2014 CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN $31,300 $0 Not Implemented
DL0121 # 02 Y:2014 02 2014 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $5,700 $0 Not Implemented
DL0121 # 03 Y:2014 03 2014 AIR CONDITION ONLY SPACE NECESSARY $22,620 $750 Not Implemented
DL0121 # 04 Y:2014 04 2014 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $19,400 $13,500 Not Implemented
DL0121 # 05 Y:2014 05 2014 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $7,400 $28,000 Not Implemented
DL0121 # 06 Y:2014 06 2014 RECOVER WASTE HEAT FROM EQUIPMENT $4,750 $1,300 Not Implemented
DL0121 # 07 Y:2014 07 2014 RECOVER WASTE HEAT FROM EQUIPMENT $4,960 $1,400 Not Implemented
DL0121 # 08 Y:2014 08 2014 INSTALL OCCUPANCY SENSORS $3,460 $3,210 Not Implemented
DL0121 # 09 Y:2014 09 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $11,200 $18,600 Not Implemented
DL0121 # 10 Y:2014 10 2014 TURN OFF EQUIPMENT WHEN NOT IN USE $1,830 $0 Not Implemented
DL0106 # 01 Y:2013 01 2013 REDUCE VENTILATION AIR $50,820 $2,200 Implemented
DL0106 # 02 Y:2013 02 2013 TURN OFF EQUIPMENT WHEN NOT IN USE $28,083 $1,516 Implemented
DL0106 # 03 Y:2013 03 2013 INSTALL SPECTRAL REFLECTORS / DELAMP $58,740 $5,580 Not Implemented
DL0106 # 04 Y:2013 04 2013 REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL $102,000 $2,375,000 Implemented
DL0106 # 05 Y:2013 05 2013 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $81,500 $11,200 Not Implemented
UA0097 # 01 Y:2013 01 2013 INSTALL TIMERS AND/OR THERMOSTATS $11,720 $2,301 Not Implemented
UA0097 # 02 Y:2013 02 2013 INSTALL TIMERS AND/OR THERMOSTATS $10,770 $3,452 Not Implemented
UA0097 # 03 Y:2013 03 2013 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $17,628 $18,309 Not Implemented
UA0097 # 04 Y:2013 04 2013 INSTALL OCCUPANCY SENSORS $3,317 $299 Not Implemented
UA0097 # 05 Y:2013 05 2013 INSTALL OCCUPANCY SENSORS $1,163 $1,646 Not Implemented
UA0097 # 06 Y:2013 06 2013 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,219 $2,500 Implemented
MA0701 # 03 Y:2012 03 2012 REDUCE VENTILATION AIR $3,642 $6,000 Not Implemented