Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,080

matching recommendations
Reset
SIC 2711 Newspapers
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0338 # 01 Y:1991 01 1991 OPTIMIZE PLANT POWER FACTOR $4,864 $10,000 Not Implemented
KU0338 # 02 Y:1991 02 1991 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $2,084 $725 Not Implemented
KU0338 # 03 Y:1991 03 1991 INSTALL SET-BACK TIMERS $1,919 $700 Not Implemented
KU0338 # 04 Y:1991 04 1991 IMPROVE LUBRICATION PRACTICES $695 $0 Not Implemented
KU0338 # 05 Y:1991 05 1991 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $695 $0 Not Implemented
KU0338 # 06 Y:1991 06 1991 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $560 $0 Not Implemented
KU0338 # 07 Y:1991 07 1991 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $383 $0 Not Implemented
TN0419 # 01 Y:1991 01 1991 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $7,626 $15,520 Not Implemented
TN0419 # 02 Y:1991 02 1991 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $2,142 $5,600 Not Implemented
TN0419 # 03 Y:1991 03 1991 INSTALL / REPAIR INSULATION ON STEAM LINES $2,007 $1,042 Not Implemented
TN0419 # 04 Y:1991 04 1991 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,300 $1,760 Not Implemented
TN0419 # 05 Y:1991 05 1991 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $618 $0 Not Implemented
TN0419 # 06 Y:1991 06 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $546 $517 Not Implemented
TN0419 # 07 Y:1991 07 1991 INSTALL SET-BACK TIMERS $417 $0 Not Implemented
TN0419 # 08 Y:1991 08 1991 OPTIMIZE PLANT POWER FACTOR $6,000 $10,000 Not Implemented
KU0328 # 01 Y:1990 01 1990 LOWER COMPRESSOR PRESSURE THROUGH A/C SYSTEM MODIFICATION $4,413 $8,400 Not Implemented
KU0328 # 02 Y:1990 02 1990 INSTALL TIMERS AND/OR THERMOSTATS $2,273 $3,200 Not Implemented
KU0328 # 03 Y:1990 03 1990 RECOVER WASTE HEAT FROM EQUIPMENT $1,446 $420 Not Implemented
KU0328 # 04 Y:1990 04 1990 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,181 $150 Not Implemented
KU0328 # 05 Y:1990 05 1990 INSTALL SET-BACK TIMERS $723 $600 Not Implemented
KU0328 # 06 Y:1990 06 1990 AIR CONDITION ONLY SPACE NECESSARY $590 $210 Not Implemented
KU0328 # 07 Y:1990 07 1990 IMPROVE LUBRICATION PRACTICES $546 $0 Implemented
KU0328 # 08 Y:1990 08 1990 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $456 $560 Not Implemented
KU0328 # 09 Y:1990 09 1990 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $339 $280 Not Implemented
KU0328 # 10 Y:1990 10 1990 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $273 $0 Not Implemented