Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
121
matching recommendationsSIC | 2731 | Book Publishing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0460 # 07 Y:1992 | 07 | 1992 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $109 | $0 | Implemented |
OR0074 # 01 Y:1989 | 01 | 1989 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $171 | $223 | Implemented |
OR0074 # 02 Y:1989 | 02 | 1989 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $1,200 | $2,400 | Not Implemented |
OR0074 # 03 Y:1989 | 03 | 1989 | OPTIMIZE PLANT POWER FACTOR | $498 | $1,125 | Implemented |
OR0074 # 04 Y:1989 | 04 | 1989 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $200 | $250 | Implemented |
KU0252 # 01 Y:1988 | 01 | 1988 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $4,182 | $7,500 | Implemented |
KU0252 # 02 Y:1988 | 02 | 1988 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,238 | $200 | Implemented |
KU0252 # 03 Y:1988 | 03 | 1988 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $2,500 | $3,600 | Not Implemented |
KU0252 # 04 Y:1988 | 04 | 1988 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $2,095 | $1,200 | Not Implemented |
KU0252 # 05 Y:1988 | 05 | 1988 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,381 | $0 | Implemented |
KU0252 # 06 Y:1988 | 06 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $308 | $0 | Implemented |
KU0252 # 07 Y:1988 | 07 | 1988 | INSTALL SET-BACK TIMERS | $1,072 | $324 | Implemented |
KU0252 # 08 Y:1988 | 08 | 1988 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $414 | $0 | Implemented |
KU0252 # 09 Y:1988 | 09 | 1988 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $167 | $200 | Not Implemented |
KU0252 # 10 Y:1988 | 10 | 1988 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $147 | $0 | Not Implemented |
KU0252 # 11 Y:1988 | 11 | 1988 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $137 | $0 | Implemented |
KU0252 # 12 Y:1988 | 12 | 1988 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $4,191 | $0 | Implemented |
KU0244 # 01 Y:1988 | 01 | 1988 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,442 | $9,509 | Implemented |
KU0244 # 02 Y:1988 | 02 | 1988 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,665 | $0 | Implemented |
KU0244 # 03 Y:1988 | 03 | 1988 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,434 | $2,355 | Not Implemented |
KU0244 # 04 Y:1988 | 04 | 1988 | MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE | $1,359 | $2,400 | Implemented |
KU0244 # 05 Y:1988 | 05 | 1988 | RECOVER WASTE HEAT FROM EQUIPMENT | $404 | $125 | Implemented |
KU0244 # 06 Y:1988 | 06 | 1988 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $324 | $0 | Implemented |
KU0244 # 07 Y:1988 | 07 | 1988 | INSTALL AUTOMATIC STACK DAMPER | $178 | $275 | Implemented |
KU0244 # 08 Y:1988 | 08 | 1988 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $174 | $10 | Not Implemented |