Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

121

matching recommendations
Reset
SIC 2731 Book Publishing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
GT0460 # 07 Y:1992 07 1992 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $109 $0 Implemented
OR0074 # 01 Y:1989 01 1989 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $171 $223 Implemented
OR0074 # 02 Y:1989 02 1989 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $1,200 $2,400 Not Implemented
OR0074 # 03 Y:1989 03 1989 OPTIMIZE PLANT POWER FACTOR $498 $1,125 Implemented
OR0074 # 04 Y:1989 04 1989 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $200 $250 Implemented
KU0252 # 01 Y:1988 01 1988 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $4,182 $7,500 Implemented
KU0252 # 02 Y:1988 02 1988 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,238 $200 Implemented
KU0252 # 03 Y:1988 03 1988 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT $2,500 $3,600 Not Implemented
KU0252 # 04 Y:1988 04 1988 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT $2,095 $1,200 Not Implemented
KU0252 # 05 Y:1988 05 1988 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,381 $0 Implemented
KU0252 # 06 Y:1988 06 1988 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $308 $0 Implemented
KU0252 # 07 Y:1988 07 1988 INSTALL SET-BACK TIMERS $1,072 $324 Implemented
KU0252 # 08 Y:1988 08 1988 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $414 $0 Implemented
KU0252 # 09 Y:1988 09 1988 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $167 $200 Not Implemented
KU0252 # 10 Y:1988 10 1988 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $147 $0 Not Implemented
KU0252 # 11 Y:1988 11 1988 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $137 $0 Implemented
KU0252 # 12 Y:1988 12 1988 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $4,191 $0 Implemented
KU0244 # 01 Y:1988 01 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,442 $9,509 Implemented
KU0244 # 02 Y:1988 02 1988 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $2,665 $0 Implemented
KU0244 # 03 Y:1988 03 1988 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $2,434 $2,355 Not Implemented
KU0244 # 04 Y:1988 04 1988 MODIFY REFRIGERATION SYSTEM TO OPERATE AT A LOWER PRESSURE $1,359 $2,400 Implemented
KU0244 # 05 Y:1988 05 1988 RECOVER WASTE HEAT FROM EQUIPMENT $404 $125 Implemented
KU0244 # 06 Y:1988 06 1988 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $324 $0 Implemented
KU0244 # 07 Y:1988 07 1988 INSTALL AUTOMATIC STACK DAMPER $178 $275 Implemented
KU0244 # 08 Y:1988 08 1988 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $174 $10 Not Implemented