Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
133
matching recommendationsSIC | 2741 | Miscellaneous Publishing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0136 # 08 Y:1996 | 08 | 1996 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $487 | $0 | Not Implemented |
UF0136 # 09 Y:1996 | 09 | 1996 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $588 | $0 | Not Implemented |
UF0136 # 10 Y:1996 | 10 | 1996 | CONVERT TO AQUEOUS CLEANING SYSTEM | $3,652 | $0 | Not Implemented |
ND0213 # 01 Y:1995 | 01 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $23,611 | $48,290 | Implemented |
ND0213 # 02 Y:1995 | 02 | 1995 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $9,837 | $5,000 | Not Implemented |
ND0213 # 03 Y:1995 | 03 | 1995 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $1,576 | $1,240 | Implemented |
ND0213 # 04 Y:1995 | 04 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,811 | $850 | Not Implemented |
ND0213 # 05 Y:1995 | 05 | 1995 | DISCONNECT BALLASTS | $1,465 | $4,733 | Not Implemented |
ND0213 # 06 Y:1995 | 06 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $615 | $1,500 | Not Implemented |
ND0213 # 07 Y:1995 | 07 | 1995 | TURN OFF EQUIPMENT WHEN NOT IN USE | $470 | $0 | Not Implemented |
ND0213 # 08 Y:1995 | 08 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $197 | $600 | Not Implemented |
ND0213 # 09 Y:1995 | 09 | 1995 | USE IN-PROCESS RECYCLING WHENEVER POSSIBLE | $94,279 | $125,000 | Implemented |
OR0124 # 01 Y:1991 | 01 | 1991 | INSTALL TIMERS AND/OR THERMOSTATS | $3,845 | $0 | Not Implemented |
OR0124 # 02 Y:1991 | 02 | 1991 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $678 | $0 | Not Implemented |
OR0124 # 03 Y:1991 | 03 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $697 | $0 | Not Implemented |
OR0124 # 04 Y:1991 | 04 | 1991 | UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT | $365 | $0 | Not Implemented |
OR0124 # 05 Y:1991 | 05 | 1991 | OPTIMIZE PLANT POWER FACTOR | $2,186 | $3,000 | Not Implemented |
OR0124 # 06 Y:1991 | 06 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $47 | $70 | Not Implemented |
OR0124 # 07 Y:1991 | 07 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $47 | $70 | Not Implemented |
OR0124 # 08 Y:1991 | 08 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,099 | $0 | Not Implemented |
AM0115 # 01 Y:1991 | 01 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,348 | $0 | Not Implemented |
AM0115 # 02 Y:1991 | 02 | 1991 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $3,600 | $7,000 | Not Implemented |
AM0115 # 03 Y:1991 | 03 | 1991 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $2,020 | $3,220 | Not Implemented |
AM0115 # 04 Y:1991 | 04 | 1991 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $923 | $40 | Not Implemented |
AM0115 # 05 Y:1991 | 05 | 1991 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $240 | $0 | Not Implemented |