Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
293
matching recommendationsSIC | 275 | Commercial Printing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0150 # 03 Y:1992 | 03 | 1992 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,493 | $0 | Not Implemented |
WI0150 # 04 Y:1992 | 04 | 1992 | INSTALL SET-BACK TIMERS | $2,039 | $600 | Not Implemented |
WI0150 # 05 Y:1992 | 05 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $8,358 | $0 | Not Implemented |
WI0150 # 06 Y:1992 | 06 | 1992 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,658 | $5,000 | Not Implemented |
WI0150 # 07 Y:1992 | 07 | 1992 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $424 | $500 | Not Implemented |
WI0150 # 08 Y:1992 | 08 | 1992 | SCHEDULE ROUTINE MAINTENANCE DURING NON-OPERATING PERIODS | $949 | $0 | Not Implemented |
WI0150 # 09 Y:1992 | 09 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $436 | $800 | Not Implemented |
WI0146 # 01 Y:1992 | 01 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,420 | $3,472 | Not Implemented |
WI0146 # 02 Y:1992 | 02 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $360 | $1,460 | Not Implemented |
WI0146 # 03 Y:1992 | 03 | 1992 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,759 | $2,350 | Implemented |
WI0146 # 04 Y:1992 | 04 | 1992 | SCHEDULE ROUTINE MAINTENANCE DURING NON-OPERATING PERIODS | $1,285 | $0 | Not Implemented |
WI0146 # 05 Y:1992 | 05 | 1992 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $836 | $0 | Not Implemented |
WI0146 # 06 Y:1992 | 06 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,269 | $2,135 | Not Implemented |
WI0146 # 07 Y:1992 | 07 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $51 | $742 | Not Implemented |
WI0146 # 08 Y:1992 | 08 | 1992 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $760 | $2,800 | Not Implemented |
WI0146 # 09 Y:1992 | 09 | 1992 | INSTALL TIMERS AND/OR THERMOSTATS | $747 | $200 | Not Implemented |
WI0146 # 10 Y:1992 | 10 | 1992 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $171 | $0 | Not Implemented |
WI0146 # 11 Y:1992 | 11 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $338 | $640 | Not Implemented |
WI0137 # 01 Y:1992 | 01 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,294 | $24 | Implemented |
WI0137 # 02 Y:1992 | 02 | 1992 | INSTALL SET-BACK TIMERS | $1,243 | $200 | Implemented |
WI0137 # 03 Y:1992 | 03 | 1992 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,150 | $0 | Not Implemented |
WI0137 # 04 Y:1992 | 04 | 1992 | INSTALL TIMERS AND/OR THERMOSTATS | $2,130 | $200 | Not Implemented |
WI0137 # 05 Y:1992 | 05 | 1992 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,093 | $700 | Implemented |
WI0137 # 06 Y:1992 | 06 | 1992 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,121 | $0 | Not Implemented |
WI0137 # 07 Y:1992 | 07 | 1992 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $841 | $0 | Implemented |