IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

260

matching recommendations
Reset
SIC 275 Commercial Printing
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UF0519 # 02 Y:2018 02 2018 OPTIMIZE PLANT POWER FACTOR $17,618 $30,000 Not Implemented
MI0310 # 05 Y:2017 05 2017 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $9,210 $2,400 Implemented
MI0310 # 01 Y:2017 01 2017 UTILIZE A LESS EXPENSIVE COOLING METHOD $66,228 $330,000 Not Implemented
MI0310 # 02 Y:2017 02 2017 TURN OFF EQUIPMENT WHEN NOT IN USE $26,938 $3,600 Implemented
MI0310 # 03 Y:2017 03 2017 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $15,634 $87,759 Implemented
MI0310 # 04 Y:2017 04 2017 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $14,676 $640 Not Implemented
MI0310 # 06 Y:2017 06 2017 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,522 $1,660 Implemented
MI0310 # 07 Y:2017 07 2017 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $3,771 $3,140 Implemented
MI0310 # 09 Y:2017 09 2017 INSTALL DRY SPRINKLER SYSTEM OR OTHER METHOD TO REDUCE HEATING REQUIREMENTS $1,743 $1,756 Implemented
MI0310 # 10 Y:2017 10 2017 INSTALL OCCUPANCY SENSORS $1,537 $5,036 Not Implemented
MI0310 # 11 Y:2017 11 2017 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,321 $1,310 Not Implemented
MI0310 # 12 Y:2017 12 2017 USE OPTIMUM SIZE AND CAPACITY EQUIPMENT $1,128 $2,500 Not Implemented
MI0310 # 13 Y:2017 13 2017 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,107 $1,700 Not Implemented
MI0310 # 08 Y:2017 08 2017 PAY UTILITY BILLS ON TIME $2,996 $0 Implemented
MI0303 # 01 Y:2016 01 2016 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,192 $28,975 Implemented
MI0303 # 02 Y:2016 02 2016 MINIMIZE WATER USAGE $6,896 $7,439 Implemented
MI0303 # 03 Y:2016 03 2016 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $6,338 $4,536 Not Implemented
MI0303 # 04 Y:2016 04 2016 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $5,274 $760 Implemented
MI0303 # 05 Y:2016 05 2016 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $2,502 $40 Not Implemented
MI0303 # 07 Y:2016 07 2016 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,786 $639 Implemented
MI0303 # 11 Y:2016 11 2016 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $541 $420 Not Implemented
MI0303 # 06 Y:2016 06 2016 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $2,425 $10,408 Implemented
MI0303 # 13 Y:2016 13 2016 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $190 $80 Implemented
MI0303 # 12 Y:2016 12 2016 MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT $325 $173 Implemented
MI0303 # 08 Y:2016 08 2016 INSTALL OCCUPANCY SENSORS $1,217 $1,149 Implemented