Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,301
matching recommendationsSIC | 275 | Commercial Printing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OD0153 # 02 Y:2000 | 02 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $871 | $20 | Not Implemented |
OD0153 # 03 Y:2000 | 03 | 2000 | INSTALL OCCUPANCY SENSORS | $405 | $285 | Not Implemented |
OD0153 # 04 Y:2000 | 04 | 2000 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $439 | $420 | Not Implemented |
OD0153 # 05 Y:2000 | 05 | 2000 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $427 | $538 | Not Implemented |
OD0153 # 06 Y:2000 | 06 | 2000 | SELL COMBUSTIBLE WASTE | $8,442 | $0 | Not Implemented |
OD0153 # 07 Y:2000 | 07 | 2000 | PAY BILLS ON TIME TO AVOID LATE FEES | $1,319 | $0 | Implemented |
UD0587 # 01 Y:2000 | 01 | 2000 | RESCHEDULE BREAKS TO ALLOW FOR CONTINUOUS PRODUCTION | $374,400 | $0 | Implemented |
UD0587 # 02 Y:2000 | 02 | 2000 | REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL | $365,350 | $1,000,000 | Not Implemented |
UD0587 # 03 Y:2000 | 03 | 2000 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $195,104 | $6,720 | Not Implemented |
UD0587 # 04 Y:2000 | 04 | 2000 | REPLACE OLD MACHINE WITH NEW AUTOMATIC MULTI-STATION TOOL | $32,550 | $0 | Implemented |
UD0587 # 05 Y:2000 | 05 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $15,175 | $39,298 | Not Implemented |
UD0587 # 06 Y:2000 | 06 | 2000 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $748 | $360 | Implemented |
TP0011 # 01 Y:2000 | 01 | 2000 | OPTIMIZE PLANT POWER FACTOR | $15,795 | $15,500 | Not Implemented |
TP0011 # 02 Y:2000 | 02 | 2000 | INSTALL OCCUPANCY SENSORS | $9,378 | $2,709 | Not Implemented |
TP0011 # 03 Y:2000 | 03 | 2000 | INSTALL SPECTRAL REFLECTORS / DELAMP | $937 | $1,725 | Not Implemented |
TP0011 # 04 Y:2000 | 04 | 2000 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $2,704 | $0 | Not Implemented |
TP0011 # 05 Y:2000 | 05 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,375 | $900 | Implemented |
TP0011 # 06 Y:2000 | 06 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $93 | $461 | Implemented |
UM0154 # 01 Y:2000 | 01 | 2000 | DISCONNECT BALLASTS | $2,608 | $880 | Implemented |
UM0154 # 02 Y:2000 | 02 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $732 | $1,400 | Not Implemented |
UM0154 # 03 Y:2000 | 03 | 2000 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,312 | $25,370 | Not Implemented |
UM0154 # 04 Y:2000 | 04 | 2000 | REDUCE VENTILATION AIR | $18,794 | $0 | Implemented |
UM0154 # 05 Y:2000 | 05 | 2000 | INCREASE AMOUNT OF WASTE RECOVERED FOR RESALE | $9,360 | $0 | Implemented |
UM0154 # 06 Y:2000 | 06 | 2000 | ADD ADDITIONAL PRODUCTION SHIFT | $1,980,000 | $568,714 | Not Implemented |
HO0218 # 01 Y:2000 | 01 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,368 | $41,546 | Implemented |