Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
44
matching recommendationsSIC | 275 | Commercial Printing |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0418 # 08 Y:2006 | 08 | 2006 | USE SOLAR HEAT TO HEAT WATER | $358 | $2,800 | n/a |
AS0418 # 07 Y:2006 | 07 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,386 | $3,000 | n/a |
AS0418 # 06 Y:2006 | 06 | 2006 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $3,394 | $1,900 | n/a |
AS0418 # 05 Y:2006 | 05 | 2006 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $4,272 | $1,000 | n/a |
AS0418 # 04 Y:2006 | 04 | 2006 | INSTALL DIRECT ACTING UNITS IN PLACE OF COMPRESSED AIR PRESSURE SYSTEM IN SAFETY SYSTEM | $6,612 | $550 | n/a |
AS0418 # 03 Y:2006 | 03 | 2006 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $12,196 | $0 | n/a |
AS0418 # 02 Y:2006 | 02 | 2006 | ELIMINATE/REDUCE REDUNDANT INSPECTIONS | $15,053 | $0 | n/a |
AS0418 # 01 Y:2006 | 01 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $21,182 | $15,913 | n/a |
AS0324 # 02 Y:2002 | 02 | 2002 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $12,718 | $4,200 | Not Implemented |
AS0324 # 09 Y:2002 | 09 | 2002 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $77,357 | $15,800 | Not Implemented |
AS0324 # 01 Y:2002 | 01 | 2002 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,071 | $1,750 | Not Implemented |
AS0324 # 03 Y:2002 | 03 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,806 | $9,004 | Implemented |
AS0324 # 04 Y:2002 | 04 | 2002 | INSTALL OCCUPANCY SENSORS | $444 | $1,400 | Not Implemented |
AS0324 # 05 Y:2002 | 05 | 2002 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $8,673 | $0 | Implemented |
AS0324 # 06 Y:2002 | 06 | 2002 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,714 | $120 | Not Implemented |
AS0324 # 07 Y:2002 | 07 | 2002 | INSTALL SKYLIGHTS | $5,831 | $6,702 | Not Implemented |
AS0324 # 08 Y:2002 | 08 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $464 | $230 | Not Implemented |
AS0324 # 10 Y:2002 | 10 | 2002 | CLEAR AND RENT EXISTING SPACE | $53,920 | $5,308 | Not Implemented |
NV0165 # 03 Y:2000 | 03 | 2000 | RECYCLE WASTE INK AND CLEANUP SOLVENT | $53,808 | $145,915 | n/a |
NV0165 # 02 Y:2000 | 02 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $140,415 | $259,240 | n/a |
NV0165 # 01 Y:2000 | 01 | 2000 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $544,084 | $20,618 | n/a |
NV0127 # 07 Y:1999 | 07 | 1999 | INSTALL SKYLIGHTS | $1,727 | $3,945 | Not Implemented |
NV0127 # 03 Y:1999 | 03 | 1999 | OPTIMIZE PLANT POWER FACTOR | $1,216 | $2,533 | Not Implemented |
NV0127 # 02 Y:1999 | 02 | 1999 | INSULATE BARE EQUIPMENT | $123 | $222 | Not Implemented |
NV0127 # 01 Y:1999 | 01 | 1999 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $704 | $1,500 | Implemented |