Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
109
matching recommendationsSIC | 2752 | Commercial Printing, Lithographic |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0534 # 02 Y:2016 | 02 | 2016 | AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM | $12,021 | $5,775 | Implemented |
SD0534 # 04 Y:2016 | 04 | 2016 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,898 | $9,052 | Implemented |
SD0534 # 06 Y:2016 | 06 | 2016 | USE PHOTOCELL CONTROLS | $2,143 | $1,850 | Not Implemented |
SD0534 # 05 Y:2016 | 05 | 2016 | USE WASTE HEAT STEAM FOR ABSORPTION REFRIGERATION | $2,674 | $2,863 | Not Implemented |
SD0534 # 03 Y:2016 | 03 | 2016 | REDUCE HEAT GAIN BY WINDOW TINTING | $5,102 | $15,750 | Not Implemented |
SD0534 # 01 Y:2016 | 01 | 2016 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $17,516 | $28,660 | Not Implemented |
SD0534 # 08 Y:2016 | 08 | 2016 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $357 | $200 | Implemented |
SD0534 # 09 Y:2016 | 09 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $548 | $180 | Not Implemented |
SF0373 # 04 Y:2009 | 04 | 2009 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $335 | $553 | Implemented |
SF0373 # 03 Y:2009 | 03 | 2009 | INSTALL OCCUPANCY SENSORS | $1,227 | $1,320 | Implemented |
SF0373 # 02 Y:2009 | 02 | 2009 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $3,700 | $3,605 | Implemented |
SF0373 # 01 Y:2009 | 01 | 2009 | REPAIR AND ELIMINATE STEAM LEAKS | $1,103 | $0 | Implemented |
SF0373 # 05 Y:2009 | 05 | 2009 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $765 | $1,569 | Not Implemented |
SF0373 # 07 Y:2009 | 07 | 2009 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,543 | $12,880 | Implemented |
SF0373 # 08 Y:2009 | 08 | 2009 | USE SOLAR HEAT TO MAKE ELECTRICTY | $32,866 | $534,450 | Not Implemented |
SF0373 # 06 Y:2009 | 06 | 2009 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $402 | $906 | Implemented |
LM0057 # 05 Y:2003 | 05 | 2003 | TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY | $47,858 | $12,520 | Implemented |
LM0057 # 04 Y:2003 | 04 | 2003 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $140,025 | $42,126 | Implemented |
LM0057 # 03 Y:2003 | 03 | 2003 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $568 | $140 | Implemented |
LM0057 # 02 Y:2003 | 02 | 2003 | ADD AREA LIGHTING SWITCHES | $2,375 | $3,580 | Implemented |
LM0057 # 01 Y:2003 | 01 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $543 | $1,430 | Implemented |
NV0154 # 05 Y:2000 | 05 | 2000 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $9,857 | $1,060 | n/a |
NV0154 # 04 Y:2000 | 04 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $16,090 | $24,980 | n/a |
NV0154 # 03 Y:2000 | 03 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,943 | $6,800 | n/a |
NV0154 # 02 Y:2000 | 02 | 2000 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,139 | $370 | n/a |