Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

109

matching recommendations
Reset
SIC 2752 Commercial Printing, Lithographic
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NV0154 # 05 Y:2000 05 2000 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $9,857 $1,060 n/a
NV0154 # 06 Y:2000 06 2000 INSTALL EQUIPMENT TO MOVE PRODUCT $3,650 $560 n/a
NV0150 # 01 Y:2000 01 2000 OPTIMIZE PLANT POWER FACTOR $1,583 $0 Not Implemented
NV0150 # 02 Y:2000 02 2000 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $357 $100 Implemented
NV0150 # 03 Y:2000 03 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $385 $3,344 Implemented
NV0150 # 04 Y:2000 04 2000 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $359 $105 Implemented
NV0150 # 05 Y:2000 05 2000 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $13,222 $10,869 Not Implemented
NV0150 # 06 Y:2000 06 2000 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $885 $304 Implemented
NV0139 # 01 Y:1999 01 1999 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,567 $600 Implemented
NV0139 # 02 Y:1999 02 1999 TURN OFF EQUIPMENT WHEN NOT IN USE $5,129 $0 Implemented
NV0139 # 03 Y:1999 03 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,871 $4,148 Implemented
NV0139 # 04 Y:1999 04 1999 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $2,592 $2,832 Not Implemented
NV0129 # 01 Y:1999 01 1999 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $154 $225 Implemented
NV0129 # 02 Y:1999 02 1999 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $230 $0 Implemented
NV0129 # 03 Y:1999 03 1999 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,578 $6,112 Not Implemented
NV0129 # 04 Y:1999 04 1999 USE RADIANT HEATER FOR SPOT HEATING $485 $1,149 Not Implemented
NV0129 # 05 Y:1999 05 1999 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $660 $400 Implemented
NV0129 # 06 Y:1999 06 1999 REGRIND, REUSE, OR SELL SCRAP PLASTIC PARTS $335 $0 Not Implemented
SD0188 # 01 Y:1998 01 1998 TURN OFF EQUIPMENT WHEN NOT IN USE $6,365 $3,993 Not Implemented
SD0188 # 02 Y:1998 02 1998 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $6,284 $0 Implemented
SD0188 # 03 Y:1998 03 1998 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $807 $405 Implemented
SD0188 # 04 Y:1998 04 1998 INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS $7,100 $8,500 Implemented
SD0188 # 05 Y:1998 05 1998 USE AN AUTOMATIC PLATE PROCESSOR $656,267 $405,000 Not Implemented
SD0188 # 06 Y:1998 06 1998 ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK $5,425 $7,000 Not Implemented
SD0187 # 01 Y:1998 01 1998 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $2,309 $3,660 Implemented