Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
176
matching recommendationsSIC | 2754 | Commercial Printing, Gravure |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0503 # 05 Y:1996 | 05 | 1996 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,143 | $31,020 | Implemented |
UD0503 # 06 Y:1996 | 06 | 1996 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,120 | $600 | Implemented |
UD0503 # 07 Y:1996 | 07 | 1996 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $5,772 | $500 | Implemented |
UD0503 # 08 Y:1996 | 08 | 1996 | PREVENT EXCESSIVE SOLVENT USAGE (OPERATOR TRAINING) | $28,200 | $0 | Implemented |
OD0044 # 01 Y:1995 | 01 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,852 | $3,186 | Implemented |
OD0044 # 02 Y:1995 | 02 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $38,154 | $31,020 | Not Implemented |
OD0044 # 03 Y:1995 | 03 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,367 | $1,000 | Implemented |
MO0141 # 01 Y:1995 | 01 | 1995 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $10,065 | $1,595 | Implemented |
MO0141 # 02 Y:1995 | 02 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $10,351 | $16,861 | Implemented |
MO0141 # 03 Y:1995 | 03 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,616 | $190 | Implemented |
MO0141 # 04 Y:1995 | 04 | 1995 | USE SYNTHETIC LUBRICANT | $4,496 | $840 | Implemented |
MO0141 # 05 Y:1995 | 05 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,611 | $12,625 | Implemented |
MO0141 # 06 Y:1995 | 06 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,356 | $490 | Implemented |
UD0438 # 01 Y:1994 | 01 | 1994 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $23,133 | $30,000 | Implemented |
UD0438 # 02 Y:1994 | 02 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $7,289 | $8,288 | Not Implemented |
UD0438 # 03 Y:1994 | 03 | 1994 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $14,232 | $27,000 | Implemented |
UD0438 # 04 Y:1994 | 04 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,367 | $6,625 | Not Implemented |
UD0438 # 05 Y:1994 | 05 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,090 | $17,120 | Not Implemented |
UD0438 # 06 Y:1994 | 06 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,413 | $1,088 | Implemented |
UD0438 # 07 Y:1994 | 07 | 1994 | TURN OFF EQUIPMENT WHEN NOT IN USE | $549 | $0 | Implemented |
UD0438 # 08 Y:1994 | 08 | 1994 | OPTIMIZE PLANT POWER FACTOR | $2,880 | $36,000 | Not Implemented |
UD0438 # 09 Y:1994 | 09 | 1994 | RECOVER WASTE HEAT FROM EQUIPMENT | $8,000 | $40,000 | Not Implemented |
UD0420 # 01 Y:1993 | 01 | 1993 | OPTIMIZE PLANT POWER FACTOR | $25,572 | $16,000 | Implemented |
UD0420 # 02 Y:1993 | 02 | 1993 | PURCHASE GAS DIRECTLY FROM A CONTRACT GAS SUPPLIER | $64,530 | $13,000 | Not Implemented |
UD0420 # 03 Y:1993 | 03 | 1993 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $14,071 | $250 | Not Implemented |