Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
543
matching recommendationsSIC | 2759 | Commercial Printing, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KG0011 # 02 Y:1994 | 02 | 1994 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $3,517 | $10,000 | Implemented |
KG0011 # 03 Y:1994 | 03 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,069 | $607 | Implemented |
KG0011 # 04 Y:1994 | 04 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $310 | $420 | Implemented |
NV0009 # 01 Y:1994 | 01 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $21,106 | $1,200 | Implemented |
NV0009 # 02 Y:1994 | 02 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,838 | $100 | Implemented |
NV0009 # 04 Y:1994 | 04 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $20,542 | $25,047 | Implemented |
NV0009 # 05 Y:1994 | 05 | 1994 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,646 | $2,200 | Implemented |
NV0009 # 06 Y:1994 | 06 | 1994 | INSTALL OCCUPANCY SENSORS | $2,237 | $80 | Implemented |
NV0009 # 07 Y:1994 | 07 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,600 | $0 | Implemented |
UD0436 # 01 Y:1994 | 01 | 1994 | OPTIMIZE PLANT POWER FACTOR | $11,729 | $21,000 | Implemented |
UD0436 # 03 Y:1994 | 03 | 1994 | RECOVER WASTE HEAT FROM EQUIPMENT | $4,381 | $7,000 | Implemented |
UD0436 # 04 Y:1994 | 04 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,299 | $15,139 | Implemented |
UD0433 # 02 Y:1994 | 02 | 1994 | REDUCE INFILTRATION TO REFRIGERATED AREAS; ISOLATE HOT EQUIPMENT FROM REFRIGERATED AREAS | $4,410 | $0 | Implemented |
UD0433 # 03 Y:1994 | 03 | 1994 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $2,059 | $300 | Implemented |
UD0433 # 05 Y:1994 | 05 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,315 | $1,950 | Implemented |
AS0118 # 01 Y:1994 | 01 | 1994 | USE HEAT PUMP FOR SPACE CONDITIONING | $10,233 | $25,000 | Implemented |
AS0118 # 05 Y:1994 | 05 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,833 | $3,220 | Implemented |
AS0118 # 06 Y:1994 | 06 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $333 | $40 | Implemented |
AS0118 # 07 Y:1994 | 07 | 1994 | INSTALL OCCUPANCY SENSORS | $1,870 | $900 | Implemented |
AS0118 # 08 Y:1994 | 08 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,788 | $4,600 | Implemented |
WI0206 # 01 Y:1994 | 01 | 1994 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $5,400 | $200 | Implemented |
WI0206 # 02 Y:1994 | 02 | 1994 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $596 | $700 | Implemented |
WI0206 # 05 Y:1994 | 05 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $771 | $1,542 | Implemented |
WI0206 # 06 Y:1994 | 06 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $219 | $324 | Implemented |
WI0206 # 07 Y:1994 | 07 | 1994 | INSTALL OCCUPANCY SENSORS | $178 | $225 | Implemented |