Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
8,673
matching recommendationsSIC | 28 | Chemicals And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UM0206 # 04 Y:2002 | 04 | 2002 | MINIMIZE CONTAMINATION OF WATER BEFORE TREATMENT | $10,650 | $26,000 | Not Implemented |
UM0206 # 05 Y:2002 | 05 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,767 | $525 | Not Implemented |
NC0228 # 01 Y:2002 | 01 | 2002 | $296,000 | $75,000 | n/a | |
NC0228 # 02 Y:2002 | 02 | 2002 | USE COMPRESSOR AIR FILTERS | $41,667 | $10,600 | n/a |
NC0228 # 03 Y:2002 | 03 | 2002 | INTERLOCK HEATING AND AIR CONDITIONING SYSTEMS TO PREVENT SIMULTANEOUS OPERATION | $173,756 | $88,000 | n/a |
NC0228 # 04 Y:2002 | 04 | 2002 | REDESIGN PROCESS | $74,974 | $100,000 | n/a |
NC0228 # 05 Y:2002 | 05 | 2002 | UTILIZE OTHER METHODS TO REMOVE CONTAMINANTS | $12,426 | $39,808 | n/a |
LE0126 # 01 Y:2002 | 01 | 2002 | INSTALL / REPAIR INSULATION ON STEAM LINES | $6,102 | $390 | Not Implemented |
LE0126 # 02 Y:2002 | 02 | 2002 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,467 | $0 | Not Implemented |
LE0126 # 03 Y:2002 | 03 | 2002 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $4,515 | $4,320 | Implemented |
LE0126 # 04 Y:2002 | 04 | 2002 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $2,573 | $2,500 | Not Implemented |
LE0126 # 05 Y:2002 | 05 | 2002 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,916 | $0 | Not Implemented |
LE0126 # 06 Y:2002 | 06 | 2002 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $1,511 | $500 | Not Implemented |
LE0126 # 07 Y:2002 | 07 | 2002 | IMPROVE LUBRICATION PRACTICES | $1,283 | $200 | Implemented |
LE0126 # 08 Y:2002 | 08 | 2002 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $653 | $0 | Not Implemented |
SF0228 # 01 Y:2002 | 01 | 2002 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $10,037 | $0 | Not Implemented |
SF0228 # 02 Y:2002 | 02 | 2002 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $19,528 | $8,550 | Not Implemented |
SF0228 # 03 Y:2002 | 03 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $16,476 | $6,382 | Implemented |
SF0228 # 04 Y:2002 | 04 | 2002 | REPLACE EXISTING CHILLER WITH HIGH EFFICIENCY MODEL | $122,694 | $120,000 | n/a |
SF0228 # 05 Y:2002 | 05 | 2002 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $565 | $480 | Not Implemented |
SF0228 # 06 Y:2002 | 06 | 2002 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $19,326 | $23,370 | Implemented |
SF0228 # 07 Y:2002 | 07 | 2002 | REDUCE FLUID FLOW RATES | $35,747 | $56,700 | n/a |
SF0228 # 08 Y:2002 | 08 | 2002 | REDUCE FLUID FLOW RATES | $6,808 | $10,340 | Not Implemented |
SF0228 # 09 Y:2002 | 09 | 2002 | REDUCE FLUID FLOW RATES | $2,958 | $5,070 | Not Implemented |
SF0228 # 10 Y:2002 | 10 | 2002 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $89,821 | $24,680 | Not Implemented |