Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
795
matching recommendationsSIC | 2819 | Industrial Inorganic Chemicals, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0633 # 05 Y:2002 | 05 | 2002 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $94,595 | $103,140 | Implemented |
OK0633 # 06 Y:2002 | 06 | 2002 | OPTIMIZE OPERATION OF MULTI-STAGE VACUUM STEAM JETS | $276,478 | $200,000 | Not Implemented |
OK0633 # 07 Y:2002 | 07 | 2002 | INSTALL WASTE HEAT BOILER TO PRODUCE STEAM | $752,359 | $502,500 | Implemented |
OK0633 # 08 Y:2002 | 08 | 2002 | USE RADIANT HEATER FOR SPOT HEATING | $5,822 | $11,440 | Not Implemented |
OK0633 # 09 Y:2002 | 09 | 2002 | INSTALL SET-BACK TIMERS | $6,660 | $3,570 | Implemented |
NC0214 # 01 Y:2001 | 01 | 2001 | USE PHOTOCELL CONTROLS | $2,595 | $2,000 | Implemented |
NC0214 # 02 Y:2001 | 02 | 2001 | RECOVER WASTE HEAT FROM EQUIPMENT | $82,133 | $143,940 | n/a |
NC0214 # 03 Y:2001 | 03 | 2001 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $158,850 | $100,000 | Implemented |
NC0214 # 04 Y:2001 | 04 | 2001 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $44,160 | $90,000 | Not Implemented |
NC0214 # 05 Y:2001 | 05 | 2001 | DEVELOP STANDARD OPERATING PROCEDURES | $3,000 | $5,000 | Not Implemented |
NC0214 # 06 Y:2001 | 06 | 2001 | DEVELOP STANDARD OPERATING PROCEDURES | $8,000 | $500 | Implemented |
NC0214 # 07 Y:2001 | 07 | 2001 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $65,115 | $86,000 | Implemented |
LE0123 # 01 Y:2001 | 01 | 2001 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $23,468 | $2,500 | Implemented |
LE0123 # 02 Y:2001 | 02 | 2001 | INSULATE FEEDWATER TANK | $14,924 | $380 | Not Implemented |
LE0123 # 03 Y:2001 | 03 | 2001 | INSULATE BARE EQUIPMENT | $57,598 | $6,000 | Implemented |
LE0123 # 04 Y:2001 | 04 | 2001 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $13,548 | $0 | Implemented |
LE0123 # 05 Y:2001 | 05 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,354 | $1,280 | Not Implemented |
LE0123 # 06 Y:2001 | 06 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $3,880 | $0 | Not Implemented |
AS0296 # 01 Y:2001 | 01 | 2001 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $800 | $1,741 | Not Implemented |
AS0296 # 02 Y:2001 | 02 | 2001 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $738 | $210 | Implemented |
AS0296 # 03 Y:2001 | 03 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $539 | $1,466 | Not Implemented |
AS0296 # 04 Y:2001 | 04 | 2001 | INSTALL OCCUPANCY SENSORS | $62 | $300 | Not Implemented |
AS0296 # 05 Y:2001 | 05 | 2001 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $1,049 | $750 | Not Implemented |
AS0296 # 06 Y:2001 | 06 | 2001 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $2,040 | $60 | Not Implemented |
AR0192 # 01 Y:2000 | 01 | 2000 | OPTIMIZE PLANT POWER FACTOR | $12,065 | $11,950 | Not Implemented |