Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
22
matching recommendationsSIC | 283 | Drugs |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MI0048 # 06 Y:2002 | 06 | 2002 | METER WASTE WATER | $577 | $1,454 | Not Implemented |
MI0048 # 05 Y:2002 | 05 | 2002 | ADD AREA LIGHTING SWITCHES | $1,911 | $350 | Implemented |
MI0048 # 04 Y:2002 | 04 | 2002 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $6,814 | $4,500 | Not Implemented |
MI0048 # 03 Y:2002 | 03 | 2002 | CLEAR AND RENT EXISTING SPACE | $123,500 | $300 | Not Implemented |
MI0048 # 02 Y:2002 | 02 | 2002 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $1,989,000 | $7,850 | Not Implemented |
MI0048 # 01 Y:2002 | 01 | 2002 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $1,989,000 | $115,000 | Implemented |
MI0047 # 02 Y:2002 | 02 | 2002 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $22,579 | $7 | Not Implemented |
MI0047 # 06 Y:2002 | 06 | 2002 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,225 | $52 | Implemented |
MI0047 # 05 Y:2002 | 05 | 2002 | ADD AREA LIGHTING SWITCHES | $10,502 | $3,900 | Not Implemented |
MI0047 # 04 Y:2002 | 04 | 2002 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $10,129 | $1,916 | Not Implemented |
MI0047 # 03 Y:2002 | 03 | 2002 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $12,504 | $209 | Not Implemented |
MI0047 # 01 Y:2002 | 01 | 2002 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $58,883 | $34,500 | n/a |
MI0045 # 05 Y:2002 | 05 | 2002 | ADD AREA LIGHTING SWITCHES | $2,961 | $1,550 | Not Implemented |
MI0045 # 04 Y:2002 | 04 | 2002 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $3,500 | $7 | Not Implemented |
MI0045 # 03 Y:2002 | 03 | 2002 | REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL | $6,814 | $5,700 | Implemented |
MI0045 # 02 Y:2002 | 02 | 2002 | DEVELOP STANDARD PROCEDURES TO IMPROVE INTERNAL YIELDS | $20,280 | $650 | Implemented |
MI0045 # 01 Y:2002 | 01 | 2002 | CHANGE PROCEDURES / EQUIPMENT / OPERATING CONDITIONS | $315,000 | $75,000 | Implemented |
MI0043 # 01 Y:2002 | 01 | 2002 | INSTALL SOFT-START TO ELIMINATE NUISANCE TRIPS | $50,836 | $17,690 | Not Implemented |
MI0043 # 05 Y:2002 | 05 | 2002 | METER WASTE WATER | $1,102 | $1,454 | Not Implemented |
MI0043 # 04 Y:2002 | 04 | 2002 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,637 | $5,036 | Not Implemented |
MI0043 # 03 Y:2002 | 03 | 2002 | IMPROVE SPACE COMFORT CONDITIONING | $3,500 | $2,000 | Implemented |
MI0043 # 02 Y:2002 | 02 | 2002 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $16,945 | $250 | Not Implemented |