Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
20
matching recommendationsSIC | 2841 | Soap And Other Detergents |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MS0173 # 02 Y:2000 | 02 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,747 | $191 | Implemented |
MS0173 # 11 Y:2000 | 11 | 2000 | PAY BILLS ON TIME TO AVOID LATE FEES | $1,514 | $50 | Not Implemented |
MS0173 # 10 Y:2000 | 10 | 2000 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $11,932 | $50 | Implemented |
MS0173 # 09 Y:2000 | 09 | 2000 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $5,488 | $50 | Implemented |
MS0173 # 08 Y:2000 | 08 | 2000 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $831 | $599 | Not Implemented |
MS0173 # 07 Y:2000 | 07 | 2000 | INSULATE BARE EQUIPMENT | $169 | $381 | Not Implemented |
MS0173 # 06 Y:2000 | 06 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $206 | $65 | Not Implemented |
MS0173 # 05 Y:2000 | 05 | 2000 | INSTALL TIMERS AND/OR THERMOSTATS | $238 | $236 | Implemented |
MS0173 # 04 Y:2000 | 04 | 2000 | USE PHOTOCELL CONTROLS | $240 | $222 | Not Implemented |
MS0173 # 03 Y:2000 | 03 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $635 | $2,618 | Not Implemented |
MS0173 # 01 Y:2000 | 01 | 2000 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $2,872 | $1,710 | Not Implemented |
UD0598 # 01 Y:2000 | 01 | 2000 | INSTALL AUTOMATIC PACKING EQUIPMENT | $1,210,579 | $375,000 | Not Implemented |
UD0598 # 02 Y:2000 | 02 | 2000 | USE CLOSED CYCLE PROCESS TO MINIMIZE WASTE WATER PRODUCTION | $22,073 | $34,288 | Implemented |
UD0598 # 03 Y:2000 | 03 | 2000 | INCREASE AMOUNT OF CONDENSATE RETURNED | $15,756 | $18,000 | Not Implemented |
UD0598 # 04 Y:2000 | 04 | 2000 | PURCHASE HIGH MATERIALS IN RETURNABLE BULK CONTAINERS | $13,603 | $0 | Not Implemented |
UD0598 # 05 Y:2000 | 05 | 2000 | CHECK FOR ACCURACY OF UTILITY / POWER METERS | $9,640 | $0 | Implemented |
UD0598 # 06 Y:2000 | 06 | 2000 | USE MINIMUM STEAM OPERATING PRESSURE | $3,333 | $0 | Implemented |
UD0598 # 07 Y:2000 | 07 | 2000 | INSTALL OCCUPANCY SENSORS | $1,752 | $726 | Not Implemented |
UD0598 # 08 Y:2000 | 08 | 2000 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $1,720 | $500 | Implemented |
UD0598 # 09 Y:2000 | 09 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,088 | $4,253 | Implemented |