Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
179
matching recommendationsSIC | 2842 | Polishes And Sanitation Goods |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0307 # 06 Y:1994 | 06 | 1994 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $340 | $980 | Not Implemented |
AM0208 # 01 Y:1994 | 01 | 1994 | OPTIMIZE PLANT POWER FACTOR | $13,375 | $16,000 | Implemented |
AM0208 # 02 Y:1994 | 02 | 1994 | TURN OFF EQUIPMENT WHEN NOT IN USE | $6,550 | $2,135 | Implemented |
AM0208 # 03 Y:1994 | 03 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,265 | $5,320 | Implemented |
AM0208 # 04 Y:1994 | 04 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,570 | $5,850 | Implemented |
AM0208 # 05 Y:1994 | 05 | 1994 | INSTALL / REPAIR INSULATION ON STEAM LINES | $815 | $1,535 | Implemented |
WI0173 # 01 Y:1993 | 01 | 1993 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $2,690 | $400 | Implemented |
WI0173 # 02 Y:1993 | 02 | 1993 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $69 | $0 | Not Implemented |
WI0173 # 03 Y:1993 | 03 | 1993 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,943 | $0 | Implemented |
WI0173 # 04 Y:1993 | 04 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $682 | $1,181 | Implemented |
WI0173 # 05 Y:1993 | 05 | 1993 | INSTALL OCCUPANCY SENSORS | $426 | $1,200 | Not Implemented |
WI0173 # 06 Y:1993 | 06 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $369 | $500 | Not Implemented |
WI0173 # 07 Y:1993 | 07 | 1993 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $959 | $1,085 | Not Implemented |
WI0173 # 08 Y:1993 | 08 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $287 | $640 | Not Implemented |
WI0173 # 09 Y:1993 | 09 | 1993 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $246 | $0 | Implemented |
WI0173 # 10 Y:1993 | 10 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $25 | $0 | Implemented |
KU0392 # 01 Y:1993 | 01 | 1993 | INSTALL TIMERS AND/OR THERMOSTATS | $10,912 | $1,720 | Not Implemented |
KU0392 # 02 Y:1993 | 02 | 1993 | RECOVER AND REUSE COOLING WATER | $7,703 | $6,000 | Not Implemented |
KU0392 # 03 Y:1993 | 03 | 1993 | INSTALL OCCUPANCY SENSORS | $5,749 | $6,500 | Not Implemented |
KU0392 # 04 Y:1993 | 04 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $141 | $0 | Not Implemented |
KU0392 # 05 Y:1993 | 05 | 1993 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $1,137 | $2,500 | Not Implemented |
KU0392 # 06 Y:1993 | 06 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,914 | $300 | Not Implemented |
KU0392 # 07 Y:1993 | 07 | 1993 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $701 | $150 | Not Implemented |
IA0046 # 01 Y:1993 | 01 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,020 | $50 | Implemented |
IA0046 # 02 Y:1993 | 02 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,060 | $150 | Implemented |