Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

498

matching recommendations
Reset
SIC 2844 Toilet Preparations
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AS0021 # 02 Y:1991 02 1991 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,782 $18,179 Implemented
AS0021 # 03 Y:1991 03 1991 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,879 $0 Implemented
AS0021 # 04 Y:1991 04 1991 UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM $12,913 $35,000 Implemented
AS0021 # 05 Y:1991 05 1991 USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT $90,586 $400,000 Implemented
AS0021 # 06 Y:1991 06 1991 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $17,386 $18,000 Implemented
AS0021 # 07 Y:1991 07 1991 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $17,885 $1,000 Implemented
AS0021 # 08 Y:1991 08 1991 RECOVER WASTE HEAT FROM EQUIPMENT $12,180 $1,760 Implemented
AS0021 # 09 Y:1991 09 1991 IMPROVE LUBRICATION PRACTICES $7,796 $0 Implemented
AS0021 # 10 Y:1991 10 1991 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $6,246 $18,000 Implemented
AS0021 # 11 Y:1991 11 1991 USE COMBINED CYCLE GAS TURBINE GENERATOR SETS WITH WASTE HEAT BOILERS CONNECTED TO TURBINE EXHAUST $101,612 $1,050,000 Implemented
TN0400 # 01 Y:1990 01 1990 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $12,739 $4,900 Not Implemented
TN0400 # 02 Y:1990 02 1990 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $7,297 $13,360 Not Implemented
TN0400 # 03 Y:1990 03 1990 KEEP LAMPS AND REFLECTORS CLEAN $8,711 $23,808 Not Implemented
TN0400 # 04 Y:1990 04 1990 INSTALL SET-BACK TIMERS $1,755 $6,350 Implemented
TN0400 # 05 Y:1990 05 1990 TURN OFF EQUIPMENT WHEN NOT IN USE $1,383 $0 Implemented
TN0400 # 06 Y:1990 06 1990 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $103 $180 Not Implemented
TN0400 # 07 Y:1990 07 1990 INSULATE BARE EQUIPMENT $280 $361 Not Implemented
MA0170 # 01 Y:1989 01 1989 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $922 $575 Not Implemented
MA0170 # 02 Y:1989 02 1989 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $614 $60 Not Implemented
MA0170 # 03 Y:1989 03 1989 INSTALL SET-BACK TIMERS $396 $195 Not Implemented
MA0170 # 04 Y:1989 04 1989 AIR CONDITION ONLY SPACE NECESSARY $4,707 $200 Not Implemented
MA0170 # 05 Y:1989 05 1989 REPAIR OR REPLACE STEAM TRAPS $355 $365 Not Implemented
MA0170 # 06 Y:1989 06 1989 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $119 $150 Not Implemented
MA0170 # 07 Y:1989 07 1989 USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE $1,248 $2,000 Not Implemented
MA0170 # 08 Y:1989 08 1989 INSTALL TIMERS AND/OR THERMOSTATS $1,999 $180 Not Implemented