IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

498

matching recommendations
Reset
SIC 2844 Toilet Preparations
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0161 # 01 Y:1989 01 1989 INSTALL / REPAIR INSULATION ON STEAM LINES $335 $703 Implemented
MA0161 # 02 Y:1989 02 1989 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $476 $1,254 Not Implemented
MA0161 # 03 Y:1989 03 1989 BURN FOSSIL FUEL TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR AND USE STEAM EXHAUST FOR HEAT $30,146 $123,000 Not Implemented
MA0161 # 04 Y:1989 04 1989 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,375 $3,000 Not Implemented
TN0330 # 01 Y:1988 01 1988 INSTALL TIMERS AND/OR THERMOSTATS $5,526 $7,320 Not Implemented
TN0330 # 02 Y:1988 02 1988 KEEP LAMPS AND REFLECTORS CLEAN $7,118 $15,836 Not Implemented
TN0330 # 04 Y:1988 04 1988 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $4,699 $1,110 Not Implemented
TN0330 # 05 Y:1988 05 1988 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $914 $0 Not Implemented
TN0330 # 06 Y:1988 06 1988 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,252 $0 Not Implemented
TN0330 # 07 Y:1988 07 1988 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $233 $310 Not Implemented
TN0330 # 08 Y:1988 08 1988 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $732 $0 Not Implemented
TN0330 # 09 Y:1988 09 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,872 $600 Not Implemented
TN0330 # 10 Y:1988 10 1988 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $464 $355 Not Implemented
TN0330 # 11 Y:1988 11 1988 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $123 $50 Not Implemented
OK0208 # 01 Y:1986 01 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $581 $97 Implemented
OK0208 # 02 Y:1986 02 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $402 $705 Implemented
OK0208 # 03 Y:1986 03 1986 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,115 $20 Implemented
OK0208 # 04 Y:1986 04 1986 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $207 $78 Implemented
UD0030 # 01 Y:1982 01 1982 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,014 $0 Implemented
UD0030 # 02 Y:1982 02 1982 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $116 $250 Not Implemented
UD0030 # 03 Y:1982 03 1982 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $995 $210 Implemented
UD0030 # 04 Y:1982 04 1982 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $1,084 $1,000 Not Implemented
UD0030 # 05 Y:1982 05 1982 REPLACE BROKEN WINDOWS AND/OR WINDOW SASH $4,094 $3,008 Implemented