Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
129
matching recommendationsSIC | 285 | Paints And Allied Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0374 # 09 Y:2000 | 09 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,934 | $940 | Not Implemented |
WI0374 # 10 Y:2000 | 10 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $514 | $120 | Implemented |
WI0374 # 11 Y:2000 | 11 | 2000 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $738 | $0 | Not Implemented |
WI0374 # 12 Y:2000 | 12 | 2000 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $426 | $2,040 | Implemented |
WI0176 # 01 Y:1993 | 01 | 1993 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $14,279 | $1,000 | Not Implemented |
WI0176 # 02 Y:1993 | 02 | 1993 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $9,577 | $0 | Implemented |
WI0176 # 03 Y:1993 | 03 | 1993 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $6,797 | $35,000 | Not Implemented |
WI0176 # 04 Y:1993 | 04 | 1993 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $4,379 | $6,300 | Not Implemented |
WI0176 # 05 Y:1993 | 05 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $3,804 | $0 | Implemented |
WI0176 # 06 Y:1993 | 06 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,917 | $8,021 | Implemented |
WI0176 # 07 Y:1993 | 07 | 1993 | USE FLUE GASES IN RADIANT HEATER FOR SPACE HEATING, OVENS, ETC | $1,633 | $1,000 | Not Implemented |
WI0176 # 08 Y:1993 | 08 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,000 | $960 | Not Implemented |
WI0176 # 09 Y:1993 | 09 | 1993 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $447 | $1,056 | Not Implemented |
WI0089 # 01 Y:1990 | 01 | 1990 | INSTALL TIMERS AND/OR THERMOSTATS | $3,012 | $1,250 | Not Implemented |
WI0089 # 02 Y:1990 | 02 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $166 | $77 | Implemented |
WI0089 # 03 Y:1990 | 03 | 1990 | INSTALL SET-BACK TIMERS | $446 | $400 | Not Implemented |
WI0089 # 04 Y:1990 | 04 | 1990 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $330 | $800 | Implemented |
WI0089 # 05 Y:1990 | 05 | 1990 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $191 | $0 | Implemented |
WI0089 # 06 Y:1990 | 06 | 1990 | RECOVER WASTE HEAT FROM EQUIPMENT | $237 | $1,000 | Not Implemented |
WI0089 # 07 Y:1990 | 07 | 1990 | INSTALL STORM WINDOWS AND DOORS | $122 | $328 | Not Implemented |
WI0061 # 01 Y:1989 | 01 | 1989 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $15,484 | $0 | Not Implemented |
WI0061 # 02 Y:1989 | 02 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,062 | $5,890 | Implemented |
WI0061 # 03 Y:1989 | 03 | 1989 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $4,969 | $0 | Implemented |
WI0061 # 04 Y:1989 | 04 | 1989 | IMPROVE LUBRICATION PRACTICES | $3,869 | $0 | Not Implemented |
WI0061 # 05 Y:1989 | 05 | 1989 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,896 | $3,000 | Implemented |