IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

19

matching recommendations
Reset
SIC 2851 Paints And Allied Products
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MU0015 # 02 Y:2022 02 2022 INSTALL OCCUPANCY SENSORS $125 $343 Implemented
MU0015 # 03 Y:2022 03 2022 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $2,649 $5,520 Not Implemented
MU0015 # 04 Y:2022 04 2022 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $6,511 $160 Implemented
MU0015 # 05 Y:2022 05 2022 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $4,565 $40,300 Implemented
MU0015 # 06 Y:2022 06 2022 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $127 $104 Implemented
MU0015 # 07 Y:2022 07 2022 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $1,257 $5,281 Implemented
MU0015 # 08 Y:2022 08 2022 KEEP EQUIPMENT CLEAN $13 $0 Implemented
MU0015 # 01 Y:2022 01 2022 TURN OFF EQUIPMENT WHEN NOT IN USE $165 $108 Implemented
ND0231 # 11 Y:1995 11 1995 RECOVER WASTE HEAT FROM EQUIPMENT $620 $500 Implemented
ND0231 # 10 Y:1995 10 1995 TURN OFF EQUIPMENT WHEN NOT IN USE $614 $0 Implemented
ND0231 # 09 Y:1995 09 1995 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $276 $335 Implemented
ND0231 # 08 Y:1995 08 1995 OPTIMIZE PLANT POWER FACTOR $5,298 $3,780 Not Implemented
ND0231 # 07 Y:1995 07 1995 COMBINE UTILITY METERS $3,325 $3,325 Not Implemented
ND0231 # 06 Y:1995 06 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $786 $828 Implemented
ND0231 # 05 Y:1995 05 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $13,304 $11,130 Implemented
ND0231 # 04 Y:1995 04 1995 USE INSULATION IN FURNACES TO FACILITATE HEATING / COOLING $70 $92 Not Implemented
ND0231 # 03 Y:1995 03 1995 DIRECT WARMEST AIR TO COMBUSTION INTAKE $1,653 $1,500 Not Implemented
ND0231 # 02 Y:1995 02 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,862 $295 Implemented
ND0231 # 01 Y:1995 01 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $645 $200 Implemented