Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

943

matching recommendations
Reset
SIC 286 Industrial Organic Chemicals
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
MA0155 # 03 Y:1989 03 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $7,948 $0 Implemented
KU0284 # 01 Y:1989 01 1989 USE WASTE HEAT TO PRODUCE STEAM TO DRIVE A STEAM TURBINE-GENERATOR $831,745 $1,230,000 Implemented
KU0284 # 02 Y:1989 02 1989 USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER $139,391 $226,000 Implemented
KU0284 # 03 Y:1989 03 1989 INSTALL SET-BACK TIMERS $16,143 $5,856 Implemented
KU0284 # 04 Y:1989 04 1989 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $4,092 $3,080 Implemented
KU0284 # 05 Y:1989 05 1989 IMPROVE LUBRICATION PRACTICES $2,169 $0 Implemented
KU0284 # 06 Y:1989 06 1989 RESCHEDULE AND REARRANGE MULTIPLE-SOURCE HEATING SYSTEMS $618 $0 Implemented
KU0284 # 07 Y:1989 07 1989 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $931 $1,018 Implemented
KU0284 # 08 Y:1989 08 1989 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $169 $0 Implemented
AM0015 # 01 Y:1987 01 1987 TURN OFF EQUIPMENT WHEN NOT IN USE $2,599 $0 Implemented
AM0015 # 02 Y:1987 02 1987 INSULATE BARE EQUIPMENT $960 $2,000 Not Implemented
AM0015 # 03 Y:1987 03 1987 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $549 $2,040 Not Implemented
AM0015 # 04 Y:1987 04 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $97 $33 Not Implemented
AM0015 # 05 Y:1987 05 1987 INSTALL TIMERS AND/OR THERMOSTATS $136 $750 Not Implemented
AM0015 # 06 Y:1987 06 1987 IMPROVE LUBRICATION PRACTICES $157 $0 Not Implemented
AM0015 # 07 Y:1987 07 1987 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $92 $0 Not Implemented
RU0013 # 01 Y:1987 01 1987 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,343 $1,050 Implemented
RU0013 # 02 Y:1987 02 1987 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $17,641 $10,500 Implemented
RU0013 # 03 Y:1987 03 1987 IMPROVE LUBRICATION PRACTICES $3,814 $1,600 Implemented
RU0013 # 04 Y:1987 04 1987 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,166 $200 Not Implemented
UD0229 # 01 Y:1987 01 1987 REDESIGN PROCESS $3,516 $0 Implemented
UD0229 # 02 Y:1987 02 1987 INCREASE AMOUNT OF CONDENSATE RETURNED $7,735 $2,000 Implemented
UD0229 # 03 Y:1987 03 1987 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $6,624 $6,000 Implemented
UD0229 # 04 Y:1987 04 1987 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $1,125 $935 Implemented
UD0229 # 05 Y:1987 05 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,776 $20,400 Implemented