Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
16
matching recommendationsSIC | 2861 | Gum And Wood Chemicals |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0590 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $19,170 | $116,000 | Not Implemented |
GT0590 # 02 Y:1996 | 02 | 1996 | REPAIR AND ELIMINATE STEAM LEAKS | $30,732 | $2,000 | Implemented |
GT0590 # 03 Y:1996 | 03 | 1996 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $11,040 | $8,800 | Not Implemented |
GT0590 # 04 Y:1996 | 04 | 1996 | ADJUST BURNERS FOR EFFICIENT OPERATION | $40,100 | $30,000 | Implemented |
GT0590 # 05 Y:1996 | 05 | 1996 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $38,880 | $60,000 | Not Implemented |
GT0590 # 06 Y:1996 | 06 | 1996 | REDUCE EXCESSIVE BOILER BLOWDOWN | $18,987 | $400 | Implemented |
GT0590 # 07 Y:1996 | 07 | 1996 | USE PHOTOCELL CONTROLS | $680 | $218 | Not Implemented |
GT0590 # 08 Y:1996 | 08 | 1996 | ELIMINATE LEAKS IN WATER LINES AND VALVES | $22,680 | $2,500 | Implemented |
GT0590 # 09 Y:1996 | 09 | 1996 | INCREASE AMOUNT OF CONDENSATE RETURNED | $34,612 | $31,200 | Implemented |
GT0445 # 01 Y:1991 | 01 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $484 | $129 | Implemented |
GT0445 # 02 Y:1991 | 02 | 1991 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $826 | $700 | Implemented |
GT0445 # 03 Y:1991 | 03 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $290 | $780 | Implemented |
GT0445 # 04 Y:1991 | 04 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $295 | $1,038 | Implemented |
GT0445 # 05 Y:1991 | 05 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $217 | $0 | Implemented |
GT0445 # 07 Y:1991 | 07 | 1991 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,410 | $500 | Implemented |
GT0445 # 08 Y:1991 | 08 | 1991 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $2,360 | $99 | Implemented |